CVE-2018-5448: CWE-23 in Medtronic 2090 CareLink Programmer
Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system.
AI Analysis
Technical Summary
CVE-2018-5448 is a directory traversal vulnerability (CWE-23) identified in the Medtronic 2090 CareLink Programmer, a medical device programmer used to manage implantable cardiac devices. The vulnerability exists within the software deployment network of the device, allowing an attacker with network access to traverse directories outside the intended file system paths. This can enable unauthorized reading of arbitrary files on the system. The flaw affects all versions of the product as of the published date in 2018. The CVSS 3.1 base score is 4.8 (medium severity), reflecting a vulnerability that requires low privileges and high attack complexity, with no user interaction needed. The attack vector is adjacent network (AV:A), meaning the attacker must have access to the same network segment. The vulnerability impacts confidentiality (high impact) but does not affect integrity or availability. No known exploits have been reported in the wild, and no patches or mitigations have been officially published by Medtronic. Given the critical nature of the device in managing cardiac implants, unauthorized file access could expose sensitive patient data or system configuration files, potentially leading to privacy violations or indirect impacts on device operation through information disclosure.
Potential Impact
For European healthcare organizations using Medtronic 2090 CareLink Programmers, this vulnerability poses a risk primarily to patient data confidentiality and system security. Unauthorized file access could reveal sensitive medical information or device configuration details, which could be leveraged for further attacks or violate GDPR regulations on personal data protection. While the vulnerability does not directly allow device manipulation or denial of service, the exposure of internal files could facilitate targeted attacks or undermine trust in medical device security. Given the critical role of these programmers in cardiac care, any compromise could have serious reputational and regulatory consequences for healthcare providers. Additionally, the requirement for network adjacency means that internal network segmentation and access controls are crucial to limit exposure. European hospitals and clinics with less mature network security practices may be at higher risk.
Mitigation Recommendations
1. Network Segmentation: Isolate the Medtronic 2090 CareLink Programmer devices on dedicated, secured network segments with strict access controls to prevent unauthorized network adjacency. 2. Access Controls: Enforce strong authentication and authorization policies for all users and systems accessing the programmer’s network. 3. Monitoring and Logging: Implement detailed logging and continuous monitoring of network traffic and file access on the programmer to detect suspicious activity indicative of directory traversal attempts. 4. Vendor Engagement: Engage with Medtronic to request official patches or security updates addressing this vulnerability. 5. File Integrity Monitoring: Deploy file integrity monitoring solutions on the programmer systems to detect unauthorized file access or changes. 6. Incident Response Preparedness: Develop and test incident response plans specific to medical device security incidents, including potential data breaches stemming from this vulnerability. 7. Limit Physical and Network Access: Restrict physical access to the devices and limit network access to trusted personnel and systems only. 8. Regular Security Assessments: Conduct periodic vulnerability assessments and penetration testing focused on medical device networks to identify and remediate similar issues.
Affected Countries
Germany, France, United Kingdom, Italy, Spain, Netherlands, Sweden, Belgium
CVE-2018-5448: CWE-23 in Medtronic 2090 CareLink Programmer
Description
Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the system.
AI-Powered Analysis
Technical Analysis
CVE-2018-5448 is a directory traversal vulnerability (CWE-23) identified in the Medtronic 2090 CareLink Programmer, a medical device programmer used to manage implantable cardiac devices. The vulnerability exists within the software deployment network of the device, allowing an attacker with network access to traverse directories outside the intended file system paths. This can enable unauthorized reading of arbitrary files on the system. The flaw affects all versions of the product as of the published date in 2018. The CVSS 3.1 base score is 4.8 (medium severity), reflecting a vulnerability that requires low privileges and high attack complexity, with no user interaction needed. The attack vector is adjacent network (AV:A), meaning the attacker must have access to the same network segment. The vulnerability impacts confidentiality (high impact) but does not affect integrity or availability. No known exploits have been reported in the wild, and no patches or mitigations have been officially published by Medtronic. Given the critical nature of the device in managing cardiac implants, unauthorized file access could expose sensitive patient data or system configuration files, potentially leading to privacy violations or indirect impacts on device operation through information disclosure.
Potential Impact
For European healthcare organizations using Medtronic 2090 CareLink Programmers, this vulnerability poses a risk primarily to patient data confidentiality and system security. Unauthorized file access could reveal sensitive medical information or device configuration details, which could be leveraged for further attacks or violate GDPR regulations on personal data protection. While the vulnerability does not directly allow device manipulation or denial of service, the exposure of internal files could facilitate targeted attacks or undermine trust in medical device security. Given the critical role of these programmers in cardiac care, any compromise could have serious reputational and regulatory consequences for healthcare providers. Additionally, the requirement for network adjacency means that internal network segmentation and access controls are crucial to limit exposure. European hospitals and clinics with less mature network security practices may be at higher risk.
Mitigation Recommendations
1. Network Segmentation: Isolate the Medtronic 2090 CareLink Programmer devices on dedicated, secured network segments with strict access controls to prevent unauthorized network adjacency. 2. Access Controls: Enforce strong authentication and authorization policies for all users and systems accessing the programmer’s network. 3. Monitoring and Logging: Implement detailed logging and continuous monitoring of network traffic and file access on the programmer to detect suspicious activity indicative of directory traversal attempts. 4. Vendor Engagement: Engage with Medtronic to request official patches or security updates addressing this vulnerability. 5. File Integrity Monitoring: Deploy file integrity monitoring solutions on the programmer systems to detect unauthorized file access or changes. 6. Incident Response Preparedness: Develop and test incident response plans specific to medical device security incidents, including potential data breaches stemming from this vulnerability. 7. Limit Physical and Network Access: Restrict physical access to the devices and limit network access to trusted personnel and systems only. 8. Regular Security Assessments: Conduct periodic vulnerability assessments and penetration testing focused on medical device networks to identify and remediate similar issues.
Affected Countries
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- icscert
- Date Reserved
- 2018-01-12T00:00:00
- Cisa Enriched
- false
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 682f64490acd01a2492644ba
Added to database: 5/22/2025, 5:52:09 PM
Last enriched: 7/8/2025, 8:54:33 AM
Last updated: 8/11/2025, 1:22:44 AM
Views: 15
Related Threats
CVE-2025-9091: Hard-coded Credentials in Tenda AC20
LowCVE-2025-9090: Command Injection in Tenda AC20
MediumCVE-2025-9092: CWE-400 Uncontrolled Resource Consumption in Legion of the Bouncy Castle Inc. Bouncy Castle for Java - BC-FJA 2.1.0
LowCVE-2025-9089: Stack-based Buffer Overflow in Tenda AC20
HighCVE-2025-9088: Stack-based Buffer Overflow in Tenda AC20
HighActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.