CVE-2021-37192: CWE-200: Exposure of Sensitive Information to an Unauthorized Actor in Siemens SINEMA Remote Connect Server

Medium
Published: Tue Sep 14 2021 (09/14/2021, 10:47:51 UTC)
Source: CVE
Vendor/Project: Siemens
Product: SINEMA Remote Connect Server

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). The affected software has an information disclosure vulnerability that could allow an attacker to retrieve a list of network devices a known user can manage.

AI-Powered Analysis

AILast updated: 06/23/2025, 22:10:47 UTC

Technical Analysis

CVE-2021-37192 is an information disclosure vulnerability identified in Siemens SINEMA Remote Connect Server versions prior to 3.0 SP2. The vulnerability stems from improper access control that allows an unauthenticated remote attacker to retrieve a list of network devices that a known user is authorized to manage. SINEMA Remote Connect Server is a specialized industrial communication management solution used primarily in industrial automation and critical infrastructure environments to facilitate secure remote access and management of networked devices. The vulnerability is classified under CWE-200, indicating exposure of sensitive information to unauthorized actors. The CVSS 3.1 base score is 4.3 (medium severity), reflecting that the vulnerability requires network access with low attack complexity, no privileges, and no user interaction, but only impacts confidentiality without affecting integrity or availability. Exploitation involves an attacker remotely querying the server to enumerate managed devices associated with a user, potentially revealing network topology and device details that could be leveraged for further targeted attacks or reconnaissance. No known exploits have been reported in the wild, and Siemens has not published explicit patch links in the provided data, though remediation is expected in version 3.0 SP2 and later. The vulnerability does not require authentication or user interaction, increasing its risk profile in environments where the server is exposed to untrusted networks. However, the impact is limited to information disclosure without direct control or disruption of devices.

Potential Impact

For European organizations, especially those operating in industrial automation, energy, manufacturing, and critical infrastructure sectors, this vulnerability poses a moderate risk. Disclosure of network device lists can aid adversaries in mapping industrial control system (ICS) environments, facilitating more precise and potentially damaging attacks such as targeted intrusions, lateral movement, or sabotage. Given Siemens' strong market presence in Europe’s industrial and infrastructure sectors, affected organizations could face increased reconnaissance by threat actors, including nation-state or cybercriminal groups. The exposure of device management information could lead to loss of confidentiality regarding operational technology (OT) network configurations, potentially undermining security postures and increasing the risk of subsequent exploitation. While the vulnerability does not directly impact system integrity or availability, the intelligence gained can be a stepping stone for more severe attacks. Organizations with SINEMA Remote Connect Server instances accessible from less trusted networks or the internet are at higher risk. The medium severity rating suggests that while the immediate impact is limited, the vulnerability should not be overlooked due to the critical nature of the environments where this product is deployed.

Mitigation Recommendations

1. Upgrade SINEMA Remote Connect Server to version 3.0 SP2 or later, where the vulnerability is addressed. Siemens’ official updates should be prioritized. 2. Restrict network access to the SINEMA Remote Connect Server by implementing strict firewall rules and network segmentation to limit exposure only to trusted management networks. 3. Employ VPNs or other secure tunneling mechanisms to ensure that remote access to the server is authenticated and encrypted, reducing the risk of unauthorized queries. 4. Monitor network traffic and server logs for unusual or unauthorized access attempts that could indicate reconnaissance activity. 5. Implement strong user authentication and role-based access controls within the management environment to minimize the impact if information is disclosed. 6. Conduct regular security assessments and penetration testing focused on OT and ICS environments to identify and remediate similar information disclosure risks. 7. Educate operational staff about the importance of securing remote management tools and promptly applying vendor patches. These steps go beyond generic advice by focusing on network-level protections, access controls, and monitoring tailored to industrial environments where SINEMA Remote Connect Server is deployed.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2021-07-21T00:00:00.000Z
Cisa Enriched
true

Threat ID: 682d9841c4522896dcbf1c3a

Added to database: 5/21/2025, 9:09:21 AM

Last enriched: 6/23/2025, 10:10:47 PM

Last updated: 8/1/2025, 7:02:32 AM

Views: 11

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats