CVE-2022-26648: CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') in Siemens SCALANCE X200-4P IRT
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.
AI Analysis
Technical Summary
CVE-2022-26648 is a classic buffer overflow vulnerability (CWE-120) affecting multiple Siemens SCALANCE industrial network switches, specifically models in the X200, XF200 series and their variants, including X200-4P IRT, X201-3P IRT, X202-2IRT, X204-2, X206-1, X208, X212-2, X216, X224, XF201-3P IRT, XF202-2P IRT, XF204, XF206-1, and XF208. All versions prior to V5.5.2 (or V5.2.6 for some models) are vulnerable. The flaw arises from improper validation of the GET parameter 'XNo' in incoming HTTP requests processed by the device's embedded web server. Specifically, the devices do not check the size of the input before copying it into a buffer, leading to a buffer overflow condition. This vulnerability can be triggered remotely by an unauthenticated attacker sending a specially crafted HTTP request with a malicious 'XNo' parameter. Exploitation results in a denial-of-service (DoS) condition by crashing the affected device. While no known exploits are reported in the wild, the vulnerability presents a risk to the availability of critical industrial network infrastructure. The affected SCALANCE switches are commonly deployed in industrial automation and control systems (IACS) environments, including manufacturing plants, utilities, and critical infrastructure sectors. The vulnerability does not require authentication or user interaction, increasing the attack surface. However, the impact is limited to device crashes rather than arbitrary code execution or data compromise. Siemens has released firmware updates (V5.5.2 or V5.2.6 and later) that address this issue by properly validating input sizes to prevent buffer overflow.
Potential Impact
The primary impact of CVE-2022-26648 on European organizations lies in the potential disruption of industrial network communications due to device crashes. SCALANCE switches are integral to industrial Ethernet networks, facilitating reliable and deterministic data exchange in automation systems. A successful attack could cause network outages, halting production lines, disrupting critical infrastructure operations such as energy distribution, transportation systems, and manufacturing processes. This could lead to operational downtime, financial losses, and safety risks in environments where continuous availability is essential. Although the vulnerability does not enable data theft or persistent compromise, the loss of network availability can have cascading effects on industrial control systems and supervisory control and data acquisition (SCADA) environments. European organizations in sectors such as automotive manufacturing, energy utilities, chemical processing, and critical infrastructure are particularly at risk due to their reliance on Siemens SCALANCE devices. The unauthenticated nature of the vulnerability increases the risk from external threat actors, including opportunistic attackers and potentially nation-state actors targeting industrial environments. Given the strategic importance of industrial automation in Europe’s economy and infrastructure, this vulnerability could be leveraged to cause targeted disruptions.
Mitigation Recommendations
1. Immediate firmware upgrade: Organizations should prioritize updating all affected Siemens SCALANCE devices to the fixed firmware versions (V5.5.2 or V5.2.6 and later) provided by Siemens. This is the definitive mitigation to eliminate the buffer overflow vulnerability. 2. Network segmentation: Isolate industrial network switches from general IT networks and restrict access to management interfaces to trusted hosts only. Use VLANs and firewalls to limit exposure of the embedded web server to untrusted networks. 3. Access control: Implement strict access control lists (ACLs) and network-level filtering to block unauthorized HTTP requests targeting the vulnerable parameter. 4. Monitoring and anomaly detection: Deploy network monitoring tools capable of detecting unusual HTTP requests or repeated malformed packets targeting SCALANCE devices. 5. Incident response readiness: Prepare for potential denial-of-service incidents by having failover or redundancy mechanisms in place for critical network paths. 6. Vendor coordination: Maintain communication with Siemens for any additional patches, advisories, or mitigation guidance. 7. Disable unnecessary services: If possible, disable the embedded web server or management interfaces not required for daily operations to reduce attack surface. 8. Physical security: Ensure physical access to network devices is controlled to prevent local exploitation or tampering.
Affected Countries
Germany, France, Italy, Spain, United Kingdom, Netherlands, Belgium, Poland, Sweden, Czech Republic
CVE-2022-26648: CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') in Siemens SCALANCE X200-4P IRT
Description
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.
AI-Powered Analysis
Technical Analysis
CVE-2022-26648 is a classic buffer overflow vulnerability (CWE-120) affecting multiple Siemens SCALANCE industrial network switches, specifically models in the X200, XF200 series and their variants, including X200-4P IRT, X201-3P IRT, X202-2IRT, X204-2, X206-1, X208, X212-2, X216, X224, XF201-3P IRT, XF202-2P IRT, XF204, XF206-1, and XF208. All versions prior to V5.5.2 (or V5.2.6 for some models) are vulnerable. The flaw arises from improper validation of the GET parameter 'XNo' in incoming HTTP requests processed by the device's embedded web server. Specifically, the devices do not check the size of the input before copying it into a buffer, leading to a buffer overflow condition. This vulnerability can be triggered remotely by an unauthenticated attacker sending a specially crafted HTTP request with a malicious 'XNo' parameter. Exploitation results in a denial-of-service (DoS) condition by crashing the affected device. While no known exploits are reported in the wild, the vulnerability presents a risk to the availability of critical industrial network infrastructure. The affected SCALANCE switches are commonly deployed in industrial automation and control systems (IACS) environments, including manufacturing plants, utilities, and critical infrastructure sectors. The vulnerability does not require authentication or user interaction, increasing the attack surface. However, the impact is limited to device crashes rather than arbitrary code execution or data compromise. Siemens has released firmware updates (V5.5.2 or V5.2.6 and later) that address this issue by properly validating input sizes to prevent buffer overflow.
Potential Impact
The primary impact of CVE-2022-26648 on European organizations lies in the potential disruption of industrial network communications due to device crashes. SCALANCE switches are integral to industrial Ethernet networks, facilitating reliable and deterministic data exchange in automation systems. A successful attack could cause network outages, halting production lines, disrupting critical infrastructure operations such as energy distribution, transportation systems, and manufacturing processes. This could lead to operational downtime, financial losses, and safety risks in environments where continuous availability is essential. Although the vulnerability does not enable data theft or persistent compromise, the loss of network availability can have cascading effects on industrial control systems and supervisory control and data acquisition (SCADA) environments. European organizations in sectors such as automotive manufacturing, energy utilities, chemical processing, and critical infrastructure are particularly at risk due to their reliance on Siemens SCALANCE devices. The unauthenticated nature of the vulnerability increases the risk from external threat actors, including opportunistic attackers and potentially nation-state actors targeting industrial environments. Given the strategic importance of industrial automation in Europe’s economy and infrastructure, this vulnerability could be leveraged to cause targeted disruptions.
Mitigation Recommendations
1. Immediate firmware upgrade: Organizations should prioritize updating all affected Siemens SCALANCE devices to the fixed firmware versions (V5.5.2 or V5.2.6 and later) provided by Siemens. This is the definitive mitigation to eliminate the buffer overflow vulnerability. 2. Network segmentation: Isolate industrial network switches from general IT networks and restrict access to management interfaces to trusted hosts only. Use VLANs and firewalls to limit exposure of the embedded web server to untrusted networks. 3. Access control: Implement strict access control lists (ACLs) and network-level filtering to block unauthorized HTTP requests targeting the vulnerable parameter. 4. Monitoring and anomaly detection: Deploy network monitoring tools capable of detecting unusual HTTP requests or repeated malformed packets targeting SCALANCE devices. 5. Incident response readiness: Prepare for potential denial-of-service incidents by having failover or redundancy mechanisms in place for critical network paths. 6. Vendor coordination: Maintain communication with Siemens for any additional patches, advisories, or mitigation guidance. 7. Disable unnecessary services: If possible, disable the embedded web server or management interfaces not required for daily operations to reduce attack surface. 8. Physical security: Ensure physical access to network devices is controlled to prevent local exploitation or tampering.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- siemens
- Date Reserved
- 2022-03-07T00:00:00.000Z
- Cisa Enriched
- true
Threat ID: 682d984bc4522896dcbf8038
Added to database: 5/21/2025, 9:09:31 AM
Last enriched: 6/20/2025, 12:50:33 PM
Last updated: 8/18/2025, 2:31:37 AM
Views: 14
Related Threats
CVE-2025-54421: CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in NamelessMC Nameless
HighCVE-2025-54118: CWE-200: Exposure of Sensitive Information to an Unauthorized Actor in NamelessMC Nameless
MediumCVE-2025-54117: CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) in NamelessMC Nameless
CriticalCVE-2025-33100: CWE-798 Use of Hard-coded Credentials in IBM Concert Software
MediumCVE-2025-33090: CWE-1333 Inefficient Regular Expression Complexity in IBM Concert Software
HighActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.