Skip to main content

CVE-2022-42733: CWE-73: External Control of File Name or Path in Siemens syngo Dynamics

High
VulnerabilityCVE-2022-42733cvecve-2022-42733cwe-73
Published: Thu Nov 17 2022 (11/17/2022, 00:00:00 UTC)
Source: CVE
Vendor/Project: Siemens
Product: syngo Dynamics

Description

A vulnerability has been identified in syngo Dynamics (All versions < VA40G HF01). syngo Dynamics application server hosts a web service using an operation with improper read access control that could allow files to be retrieved from any folder accessible to the account assigned to the website’s application pool.

AI-Powered Analysis

AILast updated: 06/22/2025, 14:06:49 UTC

Technical Analysis

CVE-2022-42733 is a high-severity vulnerability affecting Siemens' syngo Dynamics software, specifically all versions prior to VA40G HF01. syngo Dynamics is a medical imaging application server that hosts a web service. The vulnerability arises from improper read access control in one of the web service operations, which allows an attacker to retrieve files from any directory accessible to the application pool account under which the web service runs. This is classified under CWE-73: External Control of File Name or Path, indicating that the application does not properly validate or restrict file path inputs, enabling unauthorized file access. The vulnerability requires no authentication (PR:N) and no user interaction (UI:N), and can be exploited remotely over the network (AV:N) with low attack complexity (AC:L). The CVSS 3.1 base score is 7.5, reflecting a high impact on confidentiality (C:H) but no impact on integrity or availability (I:N, A:N). Exploiting this vulnerability could allow attackers to read sensitive files such as configuration files, credentials, or patient data stored on the server, potentially leading to data breaches or further attacks. No known exploits in the wild have been reported to date. Siemens has not yet published a patch link, but the vulnerability was reserved in October 2022 and published in November 2022, indicating that remediation is expected or underway. The vulnerability affects all versions before VA40G HF01, so organizations running older versions are at risk.

Potential Impact

For European organizations, particularly healthcare providers using Siemens syngo Dynamics, this vulnerability poses a significant risk to patient data confidentiality and compliance with GDPR regulations. Unauthorized file access could expose sensitive medical records, personal data, and internal configuration files, potentially leading to privacy violations, reputational damage, and regulatory penalties. Since the vulnerability can be exploited remotely without authentication, attackers could leverage it to gain initial access or reconnaissance footholds within hospital networks. The impact is heightened in environments where syngo Dynamics servers have access to broader network shares or sensitive data repositories. Additionally, healthcare infrastructure is often targeted by cybercriminals and nation-state actors, increasing the likelihood of exploitation attempts. The lack of impact on integrity and availability reduces the risk of direct service disruption but does not diminish the severity of data confidentiality breaches. Overall, this vulnerability threatens the confidentiality of critical healthcare data and could facilitate further attacks if exploited.

Mitigation Recommendations

1. Immediate upgrade: Organizations should prioritize upgrading syngo Dynamics to version VA40G HF01 or later, where the vulnerability is fixed. 2. Restrict application pool permissions: Limit the file system permissions of the application pool account hosting the web service to only necessary directories, minimizing accessible files. 3. Network segmentation: Isolate syngo Dynamics servers within segmented network zones with strict access controls to reduce exposure to untrusted networks. 4. Web service access controls: Implement additional access control mechanisms such as IP whitelisting, VPN access, or web application firewalls (WAF) to restrict who can reach the vulnerable web service endpoints. 5. Monitor and audit: Enable detailed logging and monitor access to the syngo Dynamics web service and file system for unusual or unauthorized file access patterns. 6. Incident response readiness: Prepare to respond to potential data breaches by having forensic and remediation plans in place. 7. Vendor engagement: Stay in contact with Siemens for official patches, advisories, and best practices. 8. Temporary workaround: If patching is delayed, consider disabling or restricting the vulnerable web service operation if feasible without impacting clinical operations.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2022-10-10T00:00:00.000Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d983cc4522896dcbee7d8

Added to database: 5/21/2025, 9:09:16 AM

Last enriched: 6/22/2025, 2:06:49 PM

Last updated: 8/11/2025, 11:27:44 PM