CVE-2025-7570: Buffer Overflow in UTT HiPER 840G
A vulnerability was found in UTT HiPER 840G up to 3.1.1-190328. It has been rated as critical. Affected by this issue is some unknown functionality of the file /goform/aspRemoteApConfTempSend. The manipulation of the argument remoteSrcTemp leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
AI Analysis
Technical Summary
CVE-2025-7570 is a critical buffer overflow vulnerability affecting the UTT HiPER 840G device, specifically versions up to 3.1.1-190328. The vulnerability resides in an unknown functionality related to the file /goform/aspRemoteApConfTempSend, where improper handling of the argument remoteSrcTemp allows an attacker to trigger a buffer overflow condition. This vulnerability can be exploited remotely without requiring user interaction or prior authentication, as indicated by the CVSS vector (AV:N/AC:L/AT:N/UI:N/PR:L). The buffer overflow can lead to severe consequences including remote code execution, denial of service, or system compromise due to the high impact on confidentiality, integrity, and availability (VC:H/VI:H/VA:H). The exploit has been publicly disclosed, increasing the risk of exploitation, although no known exploits have yet been observed in the wild. The vendor has not responded to early notifications, and no patches or mitigations have been officially released, leaving affected systems exposed. The vulnerability score of 8.7 (high severity) reflects the ease of exploitation combined with the critical impact potential. The attack vector being network-based and requiring low privileges makes this a significant threat for organizations using the UTT HiPER 840G device, which is likely deployed in network infrastructure environments.
Potential Impact
For European organizations, this vulnerability poses a substantial risk, especially for those relying on UTT HiPER 840G devices in their network infrastructure, such as ISPs, enterprises, and critical infrastructure providers. Successful exploitation could allow attackers to execute arbitrary code remotely, potentially leading to full device compromise, interception or manipulation of network traffic, disruption of services, and lateral movement within corporate networks. Given the device's role in network management or access point configuration, attackers could leverage this to undermine network security, exfiltrate sensitive data, or disrupt operations. The lack of vendor response and absence of patches exacerbate the risk, increasing the window of exposure. Organizations in sectors with stringent regulatory requirements (e.g., GDPR) may face compliance and reputational damage if exploited. Additionally, the public disclosure of the exploit details increases the likelihood of opportunistic attacks targeting vulnerable devices in Europe.
Mitigation Recommendations
Immediate mitigation steps include isolating affected UTT HiPER 840G devices from untrusted networks to limit exposure. Network-level protections such as firewall rules should be implemented to restrict access to the vulnerable /goform/aspRemoteApConfTempSend endpoint, if possible. Organizations should conduct thorough asset inventories to identify all instances of the affected device and version. Monitoring network traffic for anomalous requests targeting the vulnerable endpoint can help detect exploitation attempts. Employing intrusion detection/prevention systems (IDS/IPS) with custom signatures for this vulnerability is recommended. Until an official patch is released, consider deploying virtual patching via web application firewalls (WAFs) or network access controls to block malicious payloads. Engage with UTT or authorized vendors for updates or workarounds. Additionally, implement strict network segmentation to limit the impact of a compromised device and ensure regular backups of device configurations to enable rapid recovery. Finally, maintain heightened vigilance for suspicious activity and prepare incident response plans tailored to potential exploitation scenarios.
Affected Countries
Germany, France, United Kingdom, Italy, Spain, Netherlands, Poland, Belgium, Sweden, Austria
CVE-2025-7570: Buffer Overflow in UTT HiPER 840G
Description
A vulnerability was found in UTT HiPER 840G up to 3.1.1-190328. It has been rated as critical. Affected by this issue is some unknown functionality of the file /goform/aspRemoteApConfTempSend. The manipulation of the argument remoteSrcTemp leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
AI-Powered Analysis
Technical Analysis
CVE-2025-7570 is a critical buffer overflow vulnerability affecting the UTT HiPER 840G device, specifically versions up to 3.1.1-190328. The vulnerability resides in an unknown functionality related to the file /goform/aspRemoteApConfTempSend, where improper handling of the argument remoteSrcTemp allows an attacker to trigger a buffer overflow condition. This vulnerability can be exploited remotely without requiring user interaction or prior authentication, as indicated by the CVSS vector (AV:N/AC:L/AT:N/UI:N/PR:L). The buffer overflow can lead to severe consequences including remote code execution, denial of service, or system compromise due to the high impact on confidentiality, integrity, and availability (VC:H/VI:H/VA:H). The exploit has been publicly disclosed, increasing the risk of exploitation, although no known exploits have yet been observed in the wild. The vendor has not responded to early notifications, and no patches or mitigations have been officially released, leaving affected systems exposed. The vulnerability score of 8.7 (high severity) reflects the ease of exploitation combined with the critical impact potential. The attack vector being network-based and requiring low privileges makes this a significant threat for organizations using the UTT HiPER 840G device, which is likely deployed in network infrastructure environments.
Potential Impact
For European organizations, this vulnerability poses a substantial risk, especially for those relying on UTT HiPER 840G devices in their network infrastructure, such as ISPs, enterprises, and critical infrastructure providers. Successful exploitation could allow attackers to execute arbitrary code remotely, potentially leading to full device compromise, interception or manipulation of network traffic, disruption of services, and lateral movement within corporate networks. Given the device's role in network management or access point configuration, attackers could leverage this to undermine network security, exfiltrate sensitive data, or disrupt operations. The lack of vendor response and absence of patches exacerbate the risk, increasing the window of exposure. Organizations in sectors with stringent regulatory requirements (e.g., GDPR) may face compliance and reputational damage if exploited. Additionally, the public disclosure of the exploit details increases the likelihood of opportunistic attacks targeting vulnerable devices in Europe.
Mitigation Recommendations
Immediate mitigation steps include isolating affected UTT HiPER 840G devices from untrusted networks to limit exposure. Network-level protections such as firewall rules should be implemented to restrict access to the vulnerable /goform/aspRemoteApConfTempSend endpoint, if possible. Organizations should conduct thorough asset inventories to identify all instances of the affected device and version. Monitoring network traffic for anomalous requests targeting the vulnerable endpoint can help detect exploitation attempts. Employing intrusion detection/prevention systems (IDS/IPS) with custom signatures for this vulnerability is recommended. Until an official patch is released, consider deploying virtual patching via web application firewalls (WAFs) or network access controls to block malicious payloads. Engage with UTT or authorized vendors for updates or workarounds. Additionally, implement strict network segmentation to limit the impact of a compromised device and ensure regular backups of device configurations to enable rapid recovery. Finally, maintain heightened vigilance for suspicious activity and prepare incident response plans tailored to potential exploitation scenarios.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- VulDB
- Date Reserved
- 2025-07-13T07:07:49.939Z
- Cvss Version
- 4.0
- State
- PUBLISHED
Threat ID: 68748483a83201eaacc193cf
Added to database: 7/14/2025, 4:16:03 AM
Last enriched: 7/14/2025, 4:31:04 AM
Last updated: 7/16/2025, 2:20:38 AM
Views: 12
Related Threats
CVE-2025-7673: CWE-120 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') in Zyxel VMG8825-T50K firmware
CriticalCVE-2025-7359: CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') in danielriera Counter live visitors for WooCommerce
HighCVE-2025-6747: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in themefusion Avada (Fusion) Builder
MediumCVE-2025-6043: CWE-862 Missing Authorization in malcure Malcure Malware Scanner — #1 Toolset for WordPress Malware Removal
HighCVE-2025-5845: CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in wpchop Affiliate Reviews
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.