Skip to main content

CVE-2025-7884: Insufficient Verification of Data Authenticity in Eluktronics Control Center

Medium
VulnerabilityCVE-2025-7884cvecve-2025-7884
Published: Sun Jul 20 2025 (07/20/2025, 11:02:05 UTC)
Source: CVE Database V5
Vendor/Project: Eluktronics
Product: Control Center

Description

A vulnerability classified as problematic was found in Eluktronics Control Center 5.23.51.41. Affected by this vulnerability is an unknown functionality of the component REG File Handler. The manipulation leads to insufficient verification of data authenticity. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

AI-Powered Analysis

AILast updated: 07/28/2025, 01:03:33 UTC

Technical Analysis

CVE-2025-7884 is a vulnerability identified in the Eluktronics Control Center software, specifically version 5.23.51.41. The vulnerability resides in an unspecified functionality of the REG File Handler component, which is responsible for handling registry-related files or operations within the software. The core issue is insufficient verification of data authenticity, meaning that the software does not adequately validate the integrity or origin of data it processes. This flaw can be exploited locally by an attacker with limited privileges (low privileges) on the affected system. The attack does not require user interaction and can be executed without authentication, but it is limited to local access, which reduces the attack surface to users or processes already present on the host. The vulnerability has a CVSS 4.8 (medium) score, reflecting moderate severity. The vector metrics indicate low attack complexity, no user interaction, and no requirement for elevated privileges beyond low-level access. The impact primarily affects data integrity, with limited impact on confidentiality and availability. The vendor has been contacted but has not responded or issued a patch, and no known exploits are currently observed in the wild. However, the public disclosure of the vulnerability means that exploit code could be developed or shared, increasing risk over time.

Potential Impact

For European organizations using Eluktronics Control Center version 5.23.51.41, this vulnerability poses a moderate risk. Since the exploit requires local access with low privileges, the threat is mainly from insider threats, compromised user accounts, or malware that has already gained foothold on the system. Successful exploitation could allow attackers to manipulate or tamper with registry-related data handled by the software, potentially leading to unauthorized changes in system configuration or software behavior. This could degrade system integrity, cause instability, or facilitate further privilege escalation or persistence mechanisms. While the vulnerability does not directly compromise confidentiality or availability, the integrity impact can indirectly affect operational reliability and trustworthiness of affected systems. European organizations with sensitive or critical infrastructure relying on Eluktronics Control Center for system management or monitoring should be cautious, as tampering with registry data could disrupt workflows or security controls. The lack of vendor response and patch availability increases the risk exposure, especially in environments where local user access is not tightly controlled.

Mitigation Recommendations

To mitigate this vulnerability, European organizations should first identify all systems running Eluktronics Control Center version 5.23.51.41 and assess their exposure. Since no official patch is available, organizations should implement compensating controls: 1) Restrict local access to trusted users only and enforce strict access controls and user account management to minimize the risk of low-privilege exploitation. 2) Employ endpoint detection and response (EDR) solutions to monitor for suspicious activity related to registry manipulation or unauthorized local processes. 3) Use application whitelisting to prevent unauthorized execution of unknown or untrusted software that could exploit the vulnerability. 4) Regularly audit and monitor registry changes to detect unauthorized modifications early. 5) Consider isolating or segmenting systems running the vulnerable software to limit lateral movement in case of compromise. 6) Engage with Eluktronics for updates or patches and subscribe to vulnerability advisories to apply fixes promptly once available. 7) Educate users about the risks of local exploitation and enforce principle of least privilege to reduce attack surface.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
VulDB
Date Reserved
2025-07-19T07:51:49.196Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 687ccffaa83201eaac0223e2

Added to database: 7/20/2025, 11:16:10 AM

Last enriched: 7/28/2025, 1:03:33 AM

Last updated: 8/28/2025, 10:50:00 PM

Views: 37

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.