Skip to main content

CVE-1999-0214: Denial of service by sending forged ICMP unreachable packets.

High
VulnerabilityCVE-1999-0214cve-1999-0214denial of service
Published: Tue Jul 21 1992 (07/21/1992, 04:00:00 UTC)
Source: NVD
Vendor/Project: sun
Product: sunos

Description

Denial of service by sending forged ICMP unreachable packets.

AI-Powered Analysis

AILast updated: 07/01/2025, 17:43:14 UTC

Technical Analysis

CVE-1999-0214 is a high-severity vulnerability affecting SunOS versions 4.1, 4.1.1, and 4.1.2. The vulnerability arises from the operating system's handling of forged ICMP (Internet Control Message Protocol) unreachable packets. Specifically, an attacker can send crafted ICMP unreachable messages to a target system running these SunOS versions, causing a denial of service (DoS) condition. This occurs because the system improperly processes these forged packets, potentially leading to resource exhaustion or system instability that disrupts normal network operations. The vulnerability does not require authentication or user interaction and can be exploited remotely over the network, making it particularly dangerous. The CVSS score of 10 reflects the critical nature of this vulnerability, with full impact on confidentiality, integrity, and availability. Although no patches are available due to the age of the affected systems, the vulnerability remains a concern for legacy environments still running these SunOS versions.

Potential Impact

For European organizations, the impact of this vulnerability is primarily related to availability and operational continuity. Organizations that still operate legacy SunOS 4.1.x systems—common in some industrial, research, or governmental environments—may face service disruptions if targeted by attackers exploiting this vulnerability. A successful attack could lead to network outages, loss of critical services, and potential cascading failures in dependent systems. While confidentiality and integrity impacts are also rated as complete in the CVSS vector, the primary real-world effect is denial of service. Given the age of the affected systems, many European organizations have likely migrated to modern platforms; however, those with legacy infrastructure or embedded systems running SunOS could be at risk. Additionally, the lack of available patches means mitigation must rely on network-level controls and system isolation.

Mitigation Recommendations

Since no patches are available for this vulnerability, European organizations should implement the following specific mitigations: 1) Deploy network-level filtering to block or rate-limit incoming ICMP unreachable packets from untrusted sources, using firewalls or intrusion prevention systems (IPS). 2) Isolate legacy SunOS systems within segmented network zones with strict access controls to minimize exposure to external networks. 3) Monitor network traffic for unusual ICMP activity indicative of exploitation attempts. 4) Consider migrating critical services off SunOS 4.1.x systems to supported, modern operating systems to eliminate exposure. 5) Employ anomaly detection tools to identify potential denial of service patterns targeting ICMP protocols. These measures go beyond generic advice by focusing on compensating controls tailored to the absence of patches and the specific attack vector.

Need more detailed analysis?Get Pro

Threat ID: 682ca32ab6fd31d6ed7de3c9

Added to database: 5/20/2025, 3:43:38 PM

Last enriched: 7/1/2025, 5:43:14 PM

Last updated: 7/31/2025, 10:48:41 PM

Views: 11

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats