CVE-2021-37193: CWE-471: Modification of Assumed-Immutable Data (MAID) in Siemens SINEMA Remote Connect Server

0
Medium
Published: Tue Sep 14 2021 (09/14/2021, 10:47:52 UTC)
Source: CVE
Vendor/Project: Siemens
Product: SINEMA Remote Connect Server

Description

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). An unauthenticated attacker in the same network of the affected system could manipulate certain parameters and set a valid user of the affected software as invalid (or vice-versa).

AI-Powered Analysis

AILast updated: 06/23/2025, 22:10:28 UTC

Technical Analysis

CVE-2021-37193 is a medium-severity vulnerability affecting Siemens SINEMA Remote Connect Server versions prior to 3.0 SP2. The issue is classified under CWE-471, Modification of Assumed-Immutable Data (MAID). Specifically, the vulnerability allows an unauthenticated attacker who is on the same network segment as the vulnerable system to manipulate certain parameters related to user validation. This manipulation can cause the system to incorrectly mark a valid user as invalid or vice versa. The vulnerability does not impact confidentiality or availability directly but affects the integrity of user validation data. The attack vector is adjacent network (AV:A), meaning the attacker must have network access to the same local or VPN network as the server. No privileges or user interaction are required, and the attack complexity is low. The vulnerability scope is limited to the SINEMA Remote Connect Server product, which is used primarily for secure remote access to industrial control systems (ICS) and critical infrastructure environments. No known exploits have been reported in the wild, and Siemens has not provided a direct patch link in the provided information, though the issue is resolved in version 3.0 SP2 and later. The vulnerability could allow an attacker to disrupt user authentication mechanisms, potentially enabling denial of service for legitimate users or unauthorized access if combined with other weaknesses. This could undermine operational security in industrial environments relying on SINEMA Remote Connect Server for remote connectivity.

Potential Impact

For European organizations, especially those operating in industrial automation, critical infrastructure, and manufacturing sectors, this vulnerability poses a risk to the integrity of remote access controls. SINEMA Remote Connect Server is widely used in Europe for secure remote management of industrial networks. An attacker exploiting this vulnerability could disrupt user authentication, potentially locking out legitimate users or enabling unauthorized users to gain or maintain access. This could lead to operational disruptions, delayed maintenance, or unauthorized control actions in sensitive environments such as energy grids, transportation systems, and manufacturing plants. Although the vulnerability does not directly compromise confidentiality or availability, the integrity impact on user validation can cascade into broader security issues, including potential lateral movement or escalation if combined with other vulnerabilities. The requirement for network proximity limits the attack surface but does not eliminate risk, especially in environments with less segmented or poorly secured internal networks. Given the strategic importance of industrial control systems in Europe, exploitation could have significant operational and economic consequences.

Mitigation Recommendations

1. Upgrade SINEMA Remote Connect Server to version 3.0 SP2 or later, where the vulnerability is addressed. 2. Implement strict network segmentation to ensure that only trusted devices and users have access to the network segment hosting the SINEMA Remote Connect Server. 3. Employ network access controls such as VLANs, firewall rules, and NAC (Network Access Control) to restrict lateral movement and reduce the risk of an attacker gaining adjacent network access. 4. Monitor network traffic for anomalous parameter manipulation or unusual authentication failures related to SINEMA Remote Connect Server. 5. Use multi-factor authentication (MFA) where possible to add an additional layer of user verification beyond the vulnerable parameter checks. 6. Conduct regular audits of user accounts and access logs to detect any irregularities that may indicate exploitation attempts. 7. Educate network administrators and ICS security teams about the vulnerability and the importance of maintaining updated software and secure network architectures. 8. If immediate patching is not feasible, consider isolating the SINEMA Remote Connect Server on a dedicated management network with strict access controls to limit exposure.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2021-07-21T00:00:00.000Z
Cisa Enriched
true

Threat ID: 682d9841c4522896dcbf1c4b

Added to database: 5/21/2025, 9:09:21 AM

Last enriched: 6/23/2025, 10:10:28 PM

Last updated: 2/7/2026, 2:16:59 AM

Views: 36

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats