Skip to main content

CVE-2022-40282: n/a in n/a

High
VulnerabilityCVE-2022-40282cvecve-2022-40282
Published: Fri Nov 25 2022 (11/25/2022, 00:00:00 UTC)
Source: CVE
Vendor/Project: n/a
Product: n/a

Description

The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection. This allows an authenticated attacker to pass commands to the shell of the system because the dir parameter of the FsCreateDir Ajax function is not sufficiently sanitized. The vendor's ID is BSECV-2022-21.

AI-Powered Analysis

AILast updated: 06/22/2025, 11:19:52 UTC

Technical Analysis

CVE-2022-40282 is a high-severity vulnerability affecting the web server component of Hirschmann BAT-C2 devices prior to version 09.13.01.00R04. The vulnerability arises from insufficient sanitization of the 'dir' parameter in the FsCreateDir Ajax function, which allows an authenticated attacker to perform command injection. Specifically, the attacker can inject arbitrary shell commands by manipulating this parameter, leading to execution of commands on the underlying operating system with the privileges of the web server process. This vulnerability is classified under CWE-77 (Improper Neutralization of Special Elements used in a Command), indicating that user-supplied input is not properly sanitized before being passed to a system shell. The CVSS v3.1 base score is 8.8, reflecting a high impact on confidentiality, integrity, and availability, with network attack vector, low attack complexity, and requiring privileges (authenticated user) but no user interaction. Exploitation does not require additional user interaction beyond authentication, and the scope remains unchanged, meaning the impact is confined to the vulnerable component. Hirschmann BAT-C2 devices are industrial network components commonly used in critical infrastructure and industrial control systems (ICS), often deployed in environments such as manufacturing plants, energy grids, and transportation systems. The lack of available patches at the time of reporting increases the urgency for mitigation. No known exploits in the wild have been reported yet, but the nature of the vulnerability and its high CVSS score suggest a significant risk if exploited.

Potential Impact

For European organizations, especially those operating critical infrastructure sectors such as energy, manufacturing, transportation, and utilities, this vulnerability poses a significant risk. Hirschmann BAT-C2 devices are widely used in industrial networks across Europe due to Hirschmann's strong market presence in the region. Successful exploitation could allow attackers to execute arbitrary commands on these devices, potentially leading to disruption of industrial processes, data theft, or sabotage. The impact on confidentiality includes unauthorized access to sensitive operational data; integrity impact involves unauthorized modification of system configurations or operational commands; availability impact could result from denial of service or manipulation of network traffic. Given the critical role of these devices in industrial environments, exploitation could lead to operational downtime, safety hazards, and financial losses. The requirement for authentication limits the attack surface to insiders or attackers who have obtained valid credentials, but this does not eliminate the risk, as credential theft or insider threats are common attack vectors. The absence of known exploits in the wild currently provides a window for proactive defense, but the vulnerability's characteristics make it a likely target for future exploitation attempts.

Mitigation Recommendations

1. Immediate mitigation should focus on restricting access to the web server interface of Hirschmann BAT-C2 devices to trusted personnel only, using network segmentation and strict access control lists (ACLs). 2. Implement multi-factor authentication (MFA) for all users accessing the device management interfaces to reduce the risk of credential compromise. 3. Monitor and audit authentication logs and command execution logs on these devices to detect any suspicious activity indicative of exploitation attempts. 4. Employ application-layer firewalls or intrusion detection/prevention systems (IDS/IPS) capable of detecting command injection patterns targeting the 'dir' parameter in Ajax requests. 5. Until an official patch is released, consider deploying virtual patching techniques such as web application firewalls (WAFs) with custom rules to sanitize or block malicious input targeting the vulnerable function. 6. Conduct regular security awareness training for personnel with access to these devices to recognize phishing and social engineering attempts that could lead to credential compromise. 7. Engage with Hirschmann or Belden support channels to obtain updates on patch availability and apply firmware updates promptly once released. 8. For critical environments, consider implementing compensating controls such as network anomaly detection and strict change management processes to quickly identify and respond to unauthorized changes.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
mitre
Date Reserved
2022-09-08T00:00:00.000Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d983cc4522896dcbeed89

Added to database: 5/21/2025, 9:09:16 AM

Last enriched: 6/22/2025, 11:19:52 AM

Last updated: 7/30/2025, 12:01:23 AM

Views: 8

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats