Description

A vulnerability has been identified in JT2Go (All versions < V14.1.0.4), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.7), Teamcenter Visualization V14.0 (All versions < V14.0.0.3), Teamcenter Visualization V14.1 (All versions < V14.1.0.4). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.

AI-Powered Analysis

AILast updated: 06/20/2025, 11:19:22 UTC

Technical Analysis

CVE-2022-41663 is a use-after-free vulnerability identified in Siemens JT2Go and multiple versions of Teamcenter Visualization software prior to specified patch levels (JT2Go versions earlier than 14.1.0.4, Teamcenter Visualization versions earlier than 13.2.0.12, 13.3.0.7, 14.0.0.3, and 14.1.0.4). The vulnerability arises from improper memory management during the parsing of specially crafted CGM (Computer Graphics Metafile) files. Specifically, the affected applications fail to correctly handle memory that has been freed, allowing an attacker to manipulate the program's memory state. This use-after-free condition can be exploited to execute arbitrary code within the context of the affected process. Since JT2Go and Teamcenter Visualization are used for viewing and interacting with 3D CAD and visualization data, the attack vector involves convincing a user to open a malicious CGM file, which triggers the vulnerability. Successful exploitation could lead to code execution with the privileges of the user running the application, potentially allowing attackers to compromise the host system, steal sensitive intellectual property, or move laterally within a network. No known exploits have been reported in the wild as of the publication date, but the vulnerability is recognized and enriched by CISA, indicating its significance. The vulnerability is classified under CWE-416 (Use After Free), a common and dangerous memory corruption issue. Siemens has released patched versions to address this vulnerability, but no direct patch links were provided in the source information.

Potential Impact

For European organizations, the impact of this vulnerability can be significant, especially for industries relying heavily on Siemens JT2Go and Teamcenter Visualization software, such as manufacturing, automotive, aerospace, and engineering sectors. These sectors often handle sensitive design and intellectual property data, making them attractive targets for espionage or sabotage. Exploitation could lead to unauthorized code execution, resulting in data theft, disruption of design workflows, or deployment of further malware within corporate networks. Given that the vulnerability requires opening a malicious CGM file, social engineering or phishing campaigns could be used to deliver the payload. The compromise of design and visualization tools could also affect supply chain integrity and product development timelines, impacting business continuity. Additionally, if exploited in environments with elevated privileges or network access, attackers could escalate privileges or pivot to critical infrastructure systems. The absence of known exploits in the wild reduces immediate risk but does not eliminate the threat, especially as attackers often develop exploits post-disclosure. Therefore, European organizations using affected Siemens products face a medium to high risk depending on their exposure and patch management practices.

Mitigation Recommendations

1. Immediate upgrade to the latest patched versions of JT2Go and Teamcenter Visualization as specified by Siemens (versions 14.1.0.4 or later for JT2Go and corresponding patched versions for Teamcenter Visualization). 2. Implement strict file handling policies to restrict or sandbox the opening of CGM files, especially those received from untrusted or external sources. 3. Employ network segmentation to isolate systems running Siemens visualization software from critical infrastructure and sensitive data repositories. 4. Enhance user awareness training focused on recognizing and handling suspicious files and phishing attempts that may deliver malicious CGM files. 5. Utilize endpoint detection and response (EDR) solutions capable of monitoring anomalous behaviors related to memory corruption or unexpected process activity within JT2Go and Teamcenter Visualization. 6. Regularly audit and monitor logs for unusual application crashes or execution patterns that may indicate exploitation attempts. 7. If patching is delayed, consider disabling or restricting the use of CGM file formats within these applications where feasible. 8. Coordinate with Siemens support channels for any additional security advisories or mitigation tools. These targeted measures go beyond generic advice by focusing on file handling, user training, and network controls specific to the attack vector and affected products.

Need more detailed analysis?Get Pro

Technical Details

Data Version
5.1
Assigner Short Name
siemens
Date Reserved
2022-09-27T00:00:00.000Z
Cisa Enriched
true

Threat ID: 682d984bc4522896dcbf826a

Added to database: 5/21/2025, 9:09:31 AM

Last enriched: 6/20/2025, 11:19:22 AM

Last updated: 7/25/2025, 11:05:26 PM

Views: 10

Actions

PRO

Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.

Please log in to the Console to use AI analysis features.

Need enhanced features?

Contact root@offseq.com for Pro access with improved analysis and higher rate limits.

Latest Threats