CVE-2025-52579VulnerabilityPublished

CVE-2025-52579: Emerson ValveLink SOLO · CWE-316

Affects Emerson ValveLink SOLOSource CVE Database V5

0

Not known to be exploited · CVSS 9.4 Critical.

Data as of 25 Oct 2026, 19:02 UTC

CVSS 3.1 base score
9.4Critical
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.3% chance of exploitation in 30 days – higher than 32% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 10 Jul 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-25.

What to do

Affected software

ProductAffectedFixed in
Emerson ValveLink SOLOAffected
  • =0
Fixed in–

AI-suggested

Mitigation should focus on immediate and practical steps beyond generic advice. First, organizations should implement strict network segmentation and access controls to limit exposure of ValveLink SOLO systems to trusted personnel and networks only. Monitoring and logging of access to these systems should be enhanced to detect anomalous activities. Employing memory protection techniques such as encrypted memory or secure coding practices in custom integrations can reduce risk. Regularly capturing and securely handling core dumps and memory snapshots is critical; organizations should ensure these are encrypted and access-controlled. Incident response plans should be updated to include scenarios involving memory data leakage. Finally, organizations should maintain close communication with Emerson for forthcoming patches or mitigations and plan for timely deployment once available.

Description

Emerson ValveLink Products store sensitive information in cleartext in memory. The sensitive memory might be saved to disk, stored in a core dump, or remain uncleared if the product crashes, or if the programmer does not properly clear the memory before freeing it.