CVE-2025-50124: Schneider Electric EcoStruxure™ IT Data Center Expert · Improper Privilege Management

Affects Schneider Electric EcoStruxure™ IT Data Center ExpertSource CVE Database V5

0

Not known to be exploited · CVSS 7.2 High.

Data as of 26 Oct 2026, 17:16 UTC

CVSS 4.0 base score
7.2High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 11% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:P/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:L/SA:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 11 Jul 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
Schneider Electric EcoStruxure™ IT Data Center ExpertAffected
  • =8.3
Fixed in–

AI-suggested

Immediate mitigation should focus on restricting physical and console access to servers running EcoStruxure™ IT Data Center Expert, ensuring only trusted personnel have privileged account access. Implement strict monitoring and auditing of privileged account activities to detect anomalous behavior indicative of exploitation attempts. Disable or restrict use of the vulnerable setup script where possible until a vendor patch is released. Employ network segmentation to isolate management consoles from broader network access, reducing the attack surface. Enforce multi-factor authentication (MFA) for all privileged accounts to mitigate risks from credential compromise. Regularly review and minimize the number of privileged accounts to reduce potential exploitation vectors. Once Schneider Electric releases a security patch, prioritize its deployment following thorough testing. Additionally, conduct security awareness training focused on the risks of privilege misuse and the importance of secure console access.

Description

A CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation when the server is accessed by a privileged account via a console and through exploitation of a setup script.