CVE-2025-7883: Eluktronics Control Center · Command Injection
Affects Eluktronics Control CenterSource CVE Database V5
Not known to be exploited · CVSS 8.5 High.
Data as of 26 Oct 2026, 06:26 UTC
- EPSS
- 1.4% chance of exploitation in 30 days – higher than 72% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:PExploitation evidence
Disclosed: evidence found.
CVE published 20 Jul 2025
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 2026-10-26.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| Eluktronics Control Center | Affected
| Fixed in– |
AI-suggested
1. Immediate mitigation should focus on restricting local access to systems running Eluktronics Control Center 5.23.51.41 by enforcing strict physical security controls and limiting user privileges to the minimum necessary. 2. Implement application whitelisting and endpoint detection and response (EDR) solutions to monitor and block suspicious Powershell command executions that deviate from normal behavior. 3. Disable or restrict the use of the Eluktronics Control Center software if it is not essential, or remove the vulnerable component if possible. 4. Employ network segmentation to isolate devices running the vulnerable software from critical infrastructure to limit lateral movement in case of compromise. 5. Monitor logs for unusual local command execution patterns and investigate any anomalies promptly. 6. Engage with Eluktronics support channels persistently to obtain patches or official guidance, and track vulnerability advisories for updates. 7. Consider deploying host-based intrusion prevention systems (HIPS) to detect and block command injection attempts at the OS level. 8. Educate users about the risks of local privilege escalation and enforce strong authentication and endpoint security policies to reduce the likelihood of initial local access by attackers.
Description
A vulnerability classified as critical has been found in Eluktronics Control Center 5.23.51.41. Affected is an unknown function of the file \AiStoneService\MyControlCenter\Command of the component Powershell Script Handler. The manipulation leads to command injection. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.