A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.1). (CVE-2026-69108)
A local privilege escalation vulnerability exists in Siemens License Server (SLS) versions prior to 5.1 due to an insecure sudoers policy. This flaw allows a user with local access and high privileges to execute arbitrary commands as root, potentially leading to full system compromise. The vulnerability is tracked as CVE-2026-69108 and has a high severity rating with a CVSS score of 6. No official patch or remediation details are provided in the available data.
AI Analysis
Technical Summary
Siemens License Server (SLS) versions before 5.1 contain a local privilege escalation vulnerability caused by an insecure sudoers configuration. This misconfiguration allows an attacker with local access and elevated privileges to run arbitrary commands as the root user, enabling them to plant malicious files and fully compromise the system. The vulnerability is identified as CVE-2026-69108 and is associated with CWE-732 (Incorrect Permission Assignment for Critical Resource). The CVSS 3.1 base score is 6.0, reflecting local attack vector, low complexity, high privileges required, no user interaction, unchanged scope, and high impact on confidentiality and integrity but no impact on availability. No known exploits in the wild or vendor patch information are currently available.
Potential Impact
An attacker with local access and high privileges can exploit the insecure sudoers policy to execute arbitrary commands as root. This can lead to full system compromise, including unauthorized access to sensitive data and the ability to modify or plant malicious files with root privileges. The vulnerability impacts confidentiality and integrity of the affected system but does not affect availability.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict local access to trusted users only and monitor for any suspicious activity related to privilege escalation attempts. Avoid running Siemens License Server on systems where untrusted users have local access.
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V5.1). (CVE-2026-69108)
Description
A local privilege escalation vulnerability exists in Siemens License Server (SLS) versions prior to 5.1 due to an insecure sudoers policy. This flaw allows a user with local access and high privileges to execute arbitrary commands as root, potentially leading to full system compromise. The vulnerability is tracked as CVE-2026-69108 and has a high severity rating with a CVSS score of 6. No official patch or remediation details are provided in the available data.
CVSS v3.1
Score 6.0medium
Affected software
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
Siemens License Server (SLS) versions before 5.1 contain a local privilege escalation vulnerability caused by an insecure sudoers configuration. This misconfiguration allows an attacker with local access and elevated privileges to run arbitrary commands as the root user, enabling them to plant malicious files and fully compromise the system. The vulnerability is identified as CVE-2026-69108 and is associated with CWE-732 (Incorrect Permission Assignment for Critical Resource). The CVSS 3.1 base score is 6.0, reflecting local attack vector, low complexity, high privileges required, no user interaction, unchanged scope, and high impact on confidentiality and integrity but no impact on availability. No known exploits in the wild or vendor patch information are currently available.
Potential Impact
An attacker with local access and high privileges can exploit the insecure sudoers policy to execute arbitrary commands as root. This can lead to full system compromise, including unauthorized access to sensitive data and the ability to modify or plant malicious files with root privileges. The vulnerability impacts confidentiality and integrity of the affected system but does not affect availability.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict local access to trusted users only and monitor for any suspicious activity related to privilege escalation attempts. Avoid running Siemens License Server on systems where untrusted users have local access.
Technical Details
- Gcve Source
- db.gcve.eu
- Osv Id
- GHSA-gc42-c48g-89rf
- Osv Schema Version
- 1.4.0
- Aliases
- ["CVE-2026-69108"]
- Ecosystems
- []
- Database Specific Severity
- HIGH
- Cvss Version
- 3.1
Threat ID: 6a7b6fd0bf8831d5393ea16f
Added to database: 08/11/2026, 18:54:08 UTC
Last enriched: 08/11/2026, 18:59:59 UTC
Last updated: 08/12/2026, 03:40:59 UTC
Views: 4
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.