Skip to main content
EPSS 0.4%top 68%

An issue was discovered in Lantronix EDS5000 2.1.0.0R3. (CVE-2025-67037)

0
High
Published: 03/11/2026 (03/11/2026, 18:30:32 UTC)
Source: GCVE Database

Description

Lantronix EDS5000 version 2.1.0.0R3 contains a command injection vulnerability in the handling of the "tunnel" parameter when an authenticated user attempts to kill a tunnel connection. This flaw allows execution of arbitrary OS commands with root privileges, posing a high risk to system confidentiality, integrity, and availability.

CVSS v3.1

Score 8.8high

Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Affected software

Affected versions
=2.1.0.0

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 09/07/2026, 10:37:09 UTC

Technical Analysis

CVE-2025-67037 is a command injection vulnerability in Lantronix EDS5000 version 2.1.0.0R3. An authenticated attacker can inject operating system commands into the "tunnel" parameter during the process of terminating a tunnel connection. These injected commands are executed with root-level privileges, enabling full control over the affected system. The vulnerability is classified under CWE-78 (OS Command Injection) and CWE-94 (Code Injection). The CVSS v3.1 base score is 8.8, reflecting high severity with network attack vector, low attack complexity, and requiring privileges but no user interaction.

Potential Impact

Successful exploitation allows an authenticated attacker to execute arbitrary commands as root on the affected device. This can lead to complete system compromise, including unauthorized data access, modification, or destruction, and disruption of service.

Mitigation Recommendations

No official patch or remediation has been confirmed at this time. Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until a fix is available, restrict authenticated access to the device to trusted users only and monitor for suspicious activity related to tunnel management.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Gcve Source
db.gcve.eu
Osv Id
GHSA-w5v7-rqrc-ccv2
Osv Schema Version
1.4.0
Aliases
["CVE-2025-67037"]
Database Specific Severity
HIGH
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6a9c263facd9273b49fc9a3c

Added to database: 09/05/2026, 14:25:03 UTC

Last enriched: 09/07/2026, 10:37:09 UTC

Last updated: 09/10/2026, 19:42:39 UTC

Views: 4

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses