CVE-2022-36052: CWE-125: Out-of-bounds Read in contiki-ng contiki-ng
Contiki-NG is an open-source, cross-platform operating system for Next-Generation IoT devices. The 6LoWPAN implementation in Contiki-NG may cast a UDP header structure at a certain offset in a packet buffer. The code does not check whether the packet buffer is large enough to fit a full UDP header structure from the offset where the casting is made. Hence, it is possible to cause an out-of-bounds read beyond the packet buffer. The problem affects anyone running devices with Contiki-NG versions previous to 4.8, and which may receive 6LoWPAN packets from external parties. The problem has been patched in Contiki-NG version 4.8.
AI Analysis
Technical Summary
CVE-2022-36052 is a medium-severity vulnerability classified as CWE-125 (Out-of-bounds Read) affecting Contiki-NG, an open-source, cross-platform operating system designed for next-generation IoT devices. The vulnerability resides in the 6LoWPAN protocol implementation within Contiki-NG versions prior to 4.8. Specifically, the issue arises when the code attempts to cast a UDP header structure at a certain offset within a packet buffer without verifying that the buffer is sufficiently large to contain the entire UDP header from that offset. This lack of boundary checking can lead to an out-of-bounds read, where the system reads memory beyond the allocated packet buffer. Although this vulnerability does not directly allow writing or code execution, out-of-bounds reads can lead to information disclosure, potentially leaking sensitive memory contents or causing application crashes due to invalid memory access. The vulnerability affects devices running vulnerable versions of Contiki-NG that process 6LoWPAN packets from external sources, making it relevant for IoT devices using this protocol stack. The issue was addressed and patched in Contiki-NG version 4.8. There are no known exploits in the wild targeting this vulnerability as of the published date, and no CVSS score has been assigned. However, the vulnerability's root cause and potential impact warrant attention for organizations deploying Contiki-NG-based IoT devices, especially those exposed to untrusted network traffic over 6LoWPAN.
Potential Impact
For European organizations deploying IoT devices running Contiki-NG, particularly in critical infrastructure, smart city applications, industrial automation, or healthcare, this vulnerability could lead to unauthorized disclosure of sensitive information from device memory. While the vulnerability does not enable remote code execution or privilege escalation directly, the out-of-bounds read could be leveraged to gather intelligence about device internals or cause denial-of-service conditions via crashes. This is especially concerning for devices exposed to external or untrusted 6LoWPAN network traffic, such as in public IoT deployments or interconnected industrial environments. The impact is compounded by the widespread adoption of IoT technologies in Europe’s digital transformation initiatives. Confidentiality breaches could expose operational data or cryptographic material, undermining trust and compliance with data protection regulations like GDPR. Additionally, service disruptions from device instability could affect operational continuity in sectors reliant on IoT telemetry and control. Although no active exploitation is reported, the vulnerability represents a latent risk that could be exploited by advanced threat actors targeting IoT ecosystems.
Mitigation Recommendations
1. Immediate upgrade of all Contiki-NG instances to version 4.8 or later to apply the official patch addressing the out-of-bounds read. 2. Implement network-level filtering to restrict or monitor incoming 6LoWPAN traffic, especially from untrusted or external sources, reducing exposure to malformed packets. 3. Deploy intrusion detection systems (IDS) or anomaly detection tools capable of identifying unusual 6LoWPAN packet patterns or malformed UDP headers indicative of exploitation attempts. 4. Conduct thorough inventory and asset management to identify all devices running vulnerable Contiki-NG versions, including those embedded in legacy or hard-to-reach environments. 5. For devices that cannot be immediately patched, consider network segmentation or isolation to limit exposure to external 6LoWPAN traffic. 6. Engage in regular firmware and software update cycles for IoT devices, integrating vulnerability scanning and patch management into IoT lifecycle processes. 7. Collaborate with IoT device vendors and integrators to ensure secure configurations and timely updates. 8. Perform penetration testing and fuzzing on IoT networks to proactively identify similar protocol parsing vulnerabilities.
Affected Countries
Germany, France, United Kingdom, Netherlands, Italy, Spain, Sweden, Finland, Belgium, Poland
CVE-2022-36052: CWE-125: Out-of-bounds Read in contiki-ng contiki-ng
Description
Contiki-NG is an open-source, cross-platform operating system for Next-Generation IoT devices. The 6LoWPAN implementation in Contiki-NG may cast a UDP header structure at a certain offset in a packet buffer. The code does not check whether the packet buffer is large enough to fit a full UDP header structure from the offset where the casting is made. Hence, it is possible to cause an out-of-bounds read beyond the packet buffer. The problem affects anyone running devices with Contiki-NG versions previous to 4.8, and which may receive 6LoWPAN packets from external parties. The problem has been patched in Contiki-NG version 4.8.
AI-Powered Analysis
Technical Analysis
CVE-2022-36052 is a medium-severity vulnerability classified as CWE-125 (Out-of-bounds Read) affecting Contiki-NG, an open-source, cross-platform operating system designed for next-generation IoT devices. The vulnerability resides in the 6LoWPAN protocol implementation within Contiki-NG versions prior to 4.8. Specifically, the issue arises when the code attempts to cast a UDP header structure at a certain offset within a packet buffer without verifying that the buffer is sufficiently large to contain the entire UDP header from that offset. This lack of boundary checking can lead to an out-of-bounds read, where the system reads memory beyond the allocated packet buffer. Although this vulnerability does not directly allow writing or code execution, out-of-bounds reads can lead to information disclosure, potentially leaking sensitive memory contents or causing application crashes due to invalid memory access. The vulnerability affects devices running vulnerable versions of Contiki-NG that process 6LoWPAN packets from external sources, making it relevant for IoT devices using this protocol stack. The issue was addressed and patched in Contiki-NG version 4.8. There are no known exploits in the wild targeting this vulnerability as of the published date, and no CVSS score has been assigned. However, the vulnerability's root cause and potential impact warrant attention for organizations deploying Contiki-NG-based IoT devices, especially those exposed to untrusted network traffic over 6LoWPAN.
Potential Impact
For European organizations deploying IoT devices running Contiki-NG, particularly in critical infrastructure, smart city applications, industrial automation, or healthcare, this vulnerability could lead to unauthorized disclosure of sensitive information from device memory. While the vulnerability does not enable remote code execution or privilege escalation directly, the out-of-bounds read could be leveraged to gather intelligence about device internals or cause denial-of-service conditions via crashes. This is especially concerning for devices exposed to external or untrusted 6LoWPAN network traffic, such as in public IoT deployments or interconnected industrial environments. The impact is compounded by the widespread adoption of IoT technologies in Europe’s digital transformation initiatives. Confidentiality breaches could expose operational data or cryptographic material, undermining trust and compliance with data protection regulations like GDPR. Additionally, service disruptions from device instability could affect operational continuity in sectors reliant on IoT telemetry and control. Although no active exploitation is reported, the vulnerability represents a latent risk that could be exploited by advanced threat actors targeting IoT ecosystems.
Mitigation Recommendations
1. Immediate upgrade of all Contiki-NG instances to version 4.8 or later to apply the official patch addressing the out-of-bounds read. 2. Implement network-level filtering to restrict or monitor incoming 6LoWPAN traffic, especially from untrusted or external sources, reducing exposure to malformed packets. 3. Deploy intrusion detection systems (IDS) or anomaly detection tools capable of identifying unusual 6LoWPAN packet patterns or malformed UDP headers indicative of exploitation attempts. 4. Conduct thorough inventory and asset management to identify all devices running vulnerable Contiki-NG versions, including those embedded in legacy or hard-to-reach environments. 5. For devices that cannot be immediately patched, consider network segmentation or isolation to limit exposure to external 6LoWPAN traffic. 6. Engage in regular firmware and software update cycles for IoT devices, integrating vulnerability scanning and patch management into IoT lifecycle processes. 7. Collaborate with IoT device vendors and integrators to ensure secure configurations and timely updates. 8. Perform penetration testing and fuzzing on IoT networks to proactively identify similar protocol parsing vulnerabilities.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- GitHub_M
- Date Reserved
- 2022-07-15T00:00:00.000Z
- Cisa Enriched
- true
Threat ID: 682d9844c4522896dcbf3c7b
Added to database: 5/21/2025, 9:09:24 AM
Last enriched: 6/22/2025, 11:05:24 PM
Last updated: 8/11/2025, 5:43:27 PM
Views: 13
Related Threats
CVE-2025-3495: CWE-338 Use of Cryptographically Weak Pseudo-Random Number Generator (PRNG) in Delta Electronics COMMGR
CriticalCVE-2025-53948: CWE-415 Double Free in Santesoft Sante PACS Server
HighCVE-2025-52584: CWE-122 Heap-based Buffer Overflow in Ashlar-Vellum Cobalt
HighCVE-2025-46269: CWE-122 Heap-based Buffer Overflow in Ashlar-Vellum Cobalt
HighCVE-2025-54862: CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') in Santesoft Sante PACS Server
MediumActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.