CVE-2022-43397: CWE-787: Out-of-bounds Write in Siemens Parasolid V34.0
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)
AI Analysis
Technical Summary
CVE-2022-43397 is a security vulnerability identified in Siemens Parasolid versions prior to V34.0.252, V34.1 versions prior to V34.1.242, V35.0 versions prior to V35.0.170, and Simcenter Femap versions prior to 2023.1. The vulnerability is classified as CWE-787, which corresponds to an out-of-bounds write. Specifically, the issue arises during the parsing of specially crafted X_T files, which are Parasolid's native CAD file format. An out-of-bounds write occurs when the software writes data past the end of an allocated buffer, potentially corrupting adjacent memory. This memory corruption can be exploited by an attacker to execute arbitrary code within the context of the affected process. Since the vulnerability is triggered by processing maliciously crafted input files, exploitation requires the victim to open or import a compromised X_T file into the vulnerable Parasolid or Simcenter Femap software. There is no indication that authentication or elevated privileges are required to trigger the vulnerability, but user interaction is necessary to open the malicious file. No known exploits have been reported in the wild to date. Siemens has not provided direct patch links in the provided data, but affected users are advised to update to the fixed versions mentioned. The vulnerability impacts confidentiality, integrity, and availability because arbitrary code execution can lead to data theft, manipulation, or denial of service. The vulnerability affects engineering and design environments that rely on Parasolid and Simcenter Femap for 3D modeling and simulation, which are critical in manufacturing, automotive, aerospace, and industrial sectors.
Potential Impact
For European organizations, the impact of CVE-2022-43397 can be significant, especially those in sectors heavily reliant on CAD and simulation software such as automotive, aerospace, defense, and industrial manufacturing. Successful exploitation could allow attackers to execute arbitrary code, potentially leading to intellectual property theft, sabotage of design files, or disruption of engineering workflows. This could result in financial losses, reputational damage, and delays in product development cycles. Given the critical role of Siemens Parasolid and Simcenter Femap in European engineering and manufacturing ecosystems, the vulnerability poses a risk to the integrity and confidentiality of sensitive design data. Additionally, compromised systems could be leveraged as footholds for further network intrusion. The requirement for user interaction (opening a malicious file) somewhat limits remote exploitation but does not eliminate risk, especially in environments where files are shared across teams or imported from external sources. The absence of known exploits in the wild suggests a window of opportunity for organizations to remediate before active attacks emerge.
Mitigation Recommendations
1. Immediate patching: Organizations should prioritize updating Siemens Parasolid and Simcenter Femap to the fixed versions (V34.0.252 or later, V34.1.242 or later, V35.0.170 or later, and Simcenter Femap 2023.1 or later) as soon as possible. 2. File validation and sandboxing: Implement strict validation of X_T files before importing them into engineering software. Use sandbox environments to open untrusted or externally sourced CAD files to contain potential exploitation. 3. User training: Educate engineering and design teams about the risks of opening files from untrusted sources and encourage verification of file provenance. 4. Network segmentation: Isolate engineering workstations running Parasolid and Simcenter Femap from general corporate networks to limit lateral movement if exploitation occurs. 5. Monitoring and detection: Deploy endpoint detection and response (EDR) tools to monitor for anomalous behavior indicative of exploitation, such as unexpected process execution or memory corruption events. 6. Access controls: Restrict write and execution permissions on directories where X_T files are stored and processed to limit the impact of malicious files. 7. Incident response readiness: Prepare incident response plans specific to engineering environments to quickly contain and remediate any exploitation attempts.
Affected Countries
Germany, France, Italy, United Kingdom, Spain, Netherlands, Sweden, Finland, Belgium, Austria
CVE-2022-43397: CWE-787: Out-of-bounds Write in Siemens Parasolid V34.0
Description
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)
AI-Powered Analysis
Technical Analysis
CVE-2022-43397 is a security vulnerability identified in Siemens Parasolid versions prior to V34.0.252, V34.1 versions prior to V34.1.242, V35.0 versions prior to V35.0.170, and Simcenter Femap versions prior to 2023.1. The vulnerability is classified as CWE-787, which corresponds to an out-of-bounds write. Specifically, the issue arises during the parsing of specially crafted X_T files, which are Parasolid's native CAD file format. An out-of-bounds write occurs when the software writes data past the end of an allocated buffer, potentially corrupting adjacent memory. This memory corruption can be exploited by an attacker to execute arbitrary code within the context of the affected process. Since the vulnerability is triggered by processing maliciously crafted input files, exploitation requires the victim to open or import a compromised X_T file into the vulnerable Parasolid or Simcenter Femap software. There is no indication that authentication or elevated privileges are required to trigger the vulnerability, but user interaction is necessary to open the malicious file. No known exploits have been reported in the wild to date. Siemens has not provided direct patch links in the provided data, but affected users are advised to update to the fixed versions mentioned. The vulnerability impacts confidentiality, integrity, and availability because arbitrary code execution can lead to data theft, manipulation, or denial of service. The vulnerability affects engineering and design environments that rely on Parasolid and Simcenter Femap for 3D modeling and simulation, which are critical in manufacturing, automotive, aerospace, and industrial sectors.
Potential Impact
For European organizations, the impact of CVE-2022-43397 can be significant, especially those in sectors heavily reliant on CAD and simulation software such as automotive, aerospace, defense, and industrial manufacturing. Successful exploitation could allow attackers to execute arbitrary code, potentially leading to intellectual property theft, sabotage of design files, or disruption of engineering workflows. This could result in financial losses, reputational damage, and delays in product development cycles. Given the critical role of Siemens Parasolid and Simcenter Femap in European engineering and manufacturing ecosystems, the vulnerability poses a risk to the integrity and confidentiality of sensitive design data. Additionally, compromised systems could be leveraged as footholds for further network intrusion. The requirement for user interaction (opening a malicious file) somewhat limits remote exploitation but does not eliminate risk, especially in environments where files are shared across teams or imported from external sources. The absence of known exploits in the wild suggests a window of opportunity for organizations to remediate before active attacks emerge.
Mitigation Recommendations
1. Immediate patching: Organizations should prioritize updating Siemens Parasolid and Simcenter Femap to the fixed versions (V34.0.252 or later, V34.1.242 or later, V35.0.170 or later, and Simcenter Femap 2023.1 or later) as soon as possible. 2. File validation and sandboxing: Implement strict validation of X_T files before importing them into engineering software. Use sandbox environments to open untrusted or externally sourced CAD files to contain potential exploitation. 3. User training: Educate engineering and design teams about the risks of opening files from untrusted sources and encourage verification of file provenance. 4. Network segmentation: Isolate engineering workstations running Parasolid and Simcenter Femap from general corporate networks to limit lateral movement if exploitation occurs. 5. Monitoring and detection: Deploy endpoint detection and response (EDR) tools to monitor for anomalous behavior indicative of exploitation, such as unexpected process execution or memory corruption events. 6. Access controls: Restrict write and execution permissions on directories where X_T files are stored and processed to limit the impact of malicious files. 7. Incident response readiness: Prepare incident response plans specific to engineering environments to quickly contain and remediate any exploitation attempts.
For access to advanced analysis and higher rate limits, contact root@offseq.com
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- siemens
- Date Reserved
- 2022-10-18T00:00:00.000Z
- Cisa Enriched
- true
Threat ID: 682d984bc4522896dcbf829a
Added to database: 5/21/2025, 9:09:31 AM
Last enriched: 6/20/2025, 11:18:24 AM
Last updated: 7/28/2025, 8:15:53 PM
Views: 10
Related Threats
CVE-2025-8964: Improper Authentication in code-projects Hostel Management System
MediumCVE-2025-7971: CWE-20: Improper Input Validation in Rockwell Automation Studio 5000 Logix Designer®
HighCVE-2025-40758: CWE-347: Improper Verification of Cryptographic Signature in Siemens Mendix SAML (Mendix 10.12 compatible)
HighCVE-2025-36613: CWE-266: Incorrect Privilege Assignment in Dell SupportAssist for Home PCs
LowCVE-2025-27845: n/a
CriticalActions
Updates to AI analysis are available only with a Pro account. Contact root@offseq.com for access.
External Links
Need enhanced features?
Contact root@offseq.com for Pro access with improved analysis and higher rate limits.