CVE-2022-43989: CWE-306 in SICK SIM2x00 (ARM)

0
High
VulnerabilityCVE-2022-43989cvecve-2022-43989cwe-306
Published: Tue Nov 01 2022 (11/01/2022, 00:00:00 UTC)
Source: CVE
Vendor/Project: n/a
Product: SICK SIM2x00 (ARM)

Description

Password recovery vulnerability in SICK SIM2x00 (ARM) Partnumber 1092673 and 1081902 with firmware version < 1.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 1.2.0 as soon as possible (available in SICK Support Portal).

AI-Powered Analysis

AILast updated: 07/03/2025, 13:43:42 UTC

Technical Analysis

CVE-2022-43989 is a high-severity vulnerability affecting the SICK SIM2x00 (ARM) devices, specifically those with part numbers 1092673 and 1081902 running firmware versions earlier than 1.2.0. The vulnerability is classified under CWE-306, which relates to missing or insufficient authentication controls. In this case, the flaw resides in the password recovery mechanism of the device. An unprivileged remote attacker can invoke this mechanism to gain access to a user level defined as RecoverableUserLevel without proper authentication. This unauthorized access effectively elevates the attacker's privileges on the system, allowing them to compromise the confidentiality, integrity, and availability of the device and potentially the broader system it controls or monitors. The vulnerability is remotely exploitable without requiring any user interaction or prior authentication, making it particularly dangerous. The CVSS v3.1 base score is 7.3, reflecting the ease of exploitation (network vector, low attack complexity), no privileges required, and no user interaction needed, combined with impacts on confidentiality, integrity, and availability. The vulnerability is repeatable, meaning an attacker can reliably exploit it multiple times. The recommended mitigation is to update the device firmware to version 1.2.0 or later, which addresses this security flaw. This update is available through the SICK Support Portal. There are no known exploits in the wild at the time of publication, but the vulnerability's characteristics suggest it could be targeted by attackers seeking to gain unauthorized control over industrial or automation equipment using these devices.

Potential Impact

For European organizations, the impact of this vulnerability can be significant, especially for those relying on SICK SIM2x00 (ARM) devices in industrial automation, manufacturing, logistics, or safety-critical environments. Exploitation could allow attackers to gain unauthorized access and escalate privileges, potentially leading to manipulation or disruption of industrial processes, data leakage, or denial of service. This could result in operational downtime, safety hazards, financial losses, and damage to reputation. Given the critical role such devices often play in industrial control systems (ICS) and operational technology (OT) environments, the vulnerability could also be leveraged as a foothold for broader network intrusion or lateral movement. The confidentiality, integrity, and availability of systems are all at risk, which is particularly concerning in sectors like manufacturing, energy, transportation, and critical infrastructure prevalent across Europe. The fact that exploitation requires no authentication or user interaction increases the risk profile, making timely patching essential to prevent potential attacks.

Mitigation Recommendations

1. Immediate firmware update: Organizations using SICK SIM2x00 (ARM) devices with affected part numbers should prioritize updating firmware to version 1.2.0 or later, available from the SICK Support Portal. 2. Network segmentation: Isolate these devices within dedicated network segments with strict access controls to limit exposure to untrusted networks and reduce the attack surface. 3. Access control enforcement: Implement strong network-level access controls and firewall rules to restrict remote access to the devices only to authorized personnel and systems. 4. Monitoring and logging: Enable detailed logging and monitor network traffic for unusual access patterns or repeated attempts to invoke the password recovery mechanism. 5. Incident response readiness: Prepare and test incident response procedures to quickly address any signs of exploitation or compromise related to these devices. 6. Vendor communication: Maintain active communication with SICK AG for any further updates, patches, or advisories related to this vulnerability. 7. Inventory and asset management: Ensure accurate inventory of all affected devices to avoid missing any that require patching. These measures go beyond generic advice by focusing on network-level protections, proactive monitoring, and organizational preparedness tailored to the specific nature of this vulnerability and the operational context of the affected devices.

Need more detailed analysis?Upgrade to Pro Console

Technical Details

Data Version
5.1
Assigner Short Name
SICK AG
Date Reserved
2022-10-28T00:00:00.000Z
Cisa Enriched
true
Cvss Version
3.1
State
PUBLISHED

Threat ID: 682d981fc4522896dcbdca65

Added to database: 5/21/2025, 9:08:47 AM

Last enriched: 7/3/2025, 1:43:42 PM

Last updated: 2/7/2026, 7:56:21 PM

Views: 36

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console in Console -> Billing for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats