CVE-2023-51127: FLIR AX8 thermal sensor cameras · Path Traversal
Source CVE Database V5
Not known to be exploited · CVSS 7.5 High.
Data as of 26 Oct 2026, 17:16 UTC
- EPSS
- 1.2% chance of exploitation in 30 days – higher than 69% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:NExploitation evidence
Disclosed: evidence found.
CVE published 10 Jan 2024
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| n/a n/a | Affected
| Fixed in– |
AI-suggested
European organizations should immediately verify the firmware version of all deployed FLIR AX8 thermal sensor cameras and upgrade any devices running firmware versions up to 1.46.16 to at least version 1.49.16 or later, preferably the latest 1.55.16 release. Network segmentation should be employed to isolate these devices from untrusted networks, limiting exposure to potential attackers. Implement strict access controls and monitoring on the management interfaces of these cameras to detect any anomalous upload activity. Employ intrusion detection systems (IDS) or security information and event management (SIEM) solutions to alert on suspicious file upload patterns or symbolic link creations. Regularly audit device configurations and logs for signs of exploitation attempts. If firmware updates cannot be immediately applied, consider disabling remote file upload features or restricting access to trusted IP addresses only. Vendor communication channels should be monitored for any patches or advisories related to this vulnerability. Finally, incorporate this vulnerability into risk assessments and incident response plans to ensure preparedness.
Description
FLIR AX8 thermal sensor cameras up to and including 1.46.16 are vulnerable to Directory Traversal due to improper access restriction. This vulnerability allows an unauthenticated, remote attacker to obtain arbitrary sensitive file contents by uploading a specially crafted symbolic link file. NOTE: The vendor has stated that with the introduction of firmware version 1.49.16 (Jan 2023) the FLIR AX8 should no longer be affected by the vulnerability reported. Latest firmware version (as of Oct 2025, was released Jun 2024) is 1.55.16.