CVE-2024-24485: silex technology DS-600 Firmware · Improper Access Control
Source CVE Database V5
Not known to be exploited · CVSS 7.5 High.
Data as of 26 Oct 2026, 17:16 UTC
- EPSS
- 0.5% chance of exploitation in 30 days – higher than 45% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:NExploitation evidence
Disclosed: evidence found.
CVE published 15 Apr 2024
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
AI-suggested
- Network Segmentation: Isolate the DS-600 devices on dedicated network segments with strict access controls to limit exposure to untrusted networks.
- Firewall Rules: Implement firewall policies to restrict inbound traffic to the DS-600 devices, allowing only trusted management hosts to communicate with them.
- Intrusion Detection/Prevention: Deploy IDS/IPS solutions to monitor and alert on suspicious GET EEP_DATA command usage or unusual traffic patterns targeting the devices.
- Access Control: Where possible, disable or restrict the GET EEP_DATA command functionality or limit its accessibility to authenticated and authorized users only.
- Firmware Updates: Monitor silex technology advisories for patches or firmware updates addressing this vulnerability and apply them promptly once available.
- Incident Response: Prepare to investigate and respond to any signs of exploitation, including unusual data access or network scanning activities.
- Vendor Engagement: Engage with silex technology support to obtain guidance, potential workarounds, or early access to fixes.
- Asset Inventory: Maintain an accurate inventory of all DS-600 devices to ensure comprehensive coverage of mitigation efforts.
Description
An issue discovered in silex technology DS-600 Firmware v.1.4.1 allows a remote attacker to obtain sensitive information via the GET EEP_DATA command.