Skip to main content
VulnerabilityPublished

CVE-2024-28813: Infinera hiT · Improper Privilege Management

Source CVE Database V5

0

Not known to be exploited · CVSS 8.4 High.

Data as of 26 Oct 2026, 14:05 UTC

CVSS 3.1 base score
8.4High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 14% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 30 Sep 2024

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

AI-suggested

To mitigate CVE-2024-28813, organizations should immediately audit and restrict access to the @CT management application and any privileged functions within the Infinera hiT 7300 appliance. Network segmentation should be enforced to limit access to management interfaces strictly to trusted administrative hosts. Disable or restrict any undocumented or unnecessary privileged functions if possible. Monitor logs and network traffic for unusual SSH activation or connections on unexpected interfaces. Implement strict role-based access controls and multi-factor authentication for all privileged users to reduce the risk of insider threats or credential compromise. Regularly review and update firewall rules to block unauthorized access to network interfaces that should not accept SSH connections. Engage with Infinera support to obtain guidance on patches or firmware updates addressing this vulnerability and apply them promptly once available. Consider deploying network intrusion detection systems tuned to detect anomalous management activity. Finally, conduct security awareness training for administrators to recognize and report suspicious behavior related to device management.

Description

An issue was discovered in Infinera hiT 7300 5.60.50. Undocumented privileged functions in the @CT management application allow an attacker to activate remote SSH access to the appliance via an unexpected network interface.