CVE-2024-29296: n/a
A user enumeration vulnerability was found in Portainer CE 2.19.4. This issue occurs during user authentication process, where a difference in response time could allow a remote unauthenticated user to determine if a username is valid or not.
AI Analysis
Technical Summary
CVE-2024-29296 identifies a user enumeration vulnerability in Portainer Community Edition (CE) version 2.19.4. The flaw arises during the user authentication process, where the application responds with different timing delays depending on whether a submitted username exists or not. This timing discrepancy can be remotely observed by an unauthenticated attacker, enabling them to confirm the validity of usernames without needing credentials or user interaction. The vulnerability is classified under CWE-286 (Improper Authorization), as it leaks information that should be protected. The CVSS v3.1 base score is 5.3, reflecting a medium severity impact primarily on confidentiality. The vulnerability does not affect the integrity or availability of the system. No patches or fixes are currently linked, and no known exploits have been reported in the wild. However, the ability to enumerate valid usernames can significantly aid attackers in crafting targeted attacks such as password guessing, brute force, or social engineering campaigns. Portainer CE is a widely used open-source container management platform that simplifies Docker and Kubernetes management, making this vulnerability relevant to organizations leveraging containerized environments. The issue highlights the importance of consistent response times and error messages during authentication to prevent side-channel information leaks.
Potential Impact
The primary impact of CVE-2024-29296 is the compromise of confidentiality through user enumeration. Attackers can remotely identify valid usernames on Portainer CE instances without authentication, which can be leveraged to facilitate further attacks such as brute force password attempts, credential stuffing, or targeted phishing campaigns. Although the vulnerability does not directly affect system integrity or availability, the exposure of valid user accounts increases the attack surface and risk of unauthorized access if combined with other vulnerabilities or weak credentials. Organizations relying on Portainer CE for container management may face increased risk of account compromise, potentially leading to unauthorized container deployments, data exposure, or lateral movement within infrastructure. The medium CVSS score reflects that while exploitation is relatively straightforward and impactful for reconnaissance, it does not directly cause system disruption or data modification. The absence of known exploits in the wild suggests limited immediate threat, but the vulnerability should be addressed proactively to prevent future exploitation.
Mitigation Recommendations
To mitigate CVE-2024-29296, organizations should: 1) Monitor Portainer CE vendor communications closely and apply security patches or updates promptly once available to address the timing discrepancy. 2) Implement uniform response times and error messages during authentication processes to eliminate timing side channels that reveal username validity. This can be achieved by introducing artificial delays or consistent error handling regardless of username correctness. 3) Employ multi-factor authentication (MFA) on Portainer CE accounts to reduce the risk of account compromise even if usernames are enumerated. 4) Enforce strong password policies and consider account lockout or throttling mechanisms after repeated failed login attempts to hinder brute force attacks. 5) Monitor authentication logs for unusual patterns indicative of enumeration or brute force attempts and respond with incident handling procedures. 6) Restrict access to Portainer CE management interfaces to trusted networks or VPNs to reduce exposure to unauthenticated remote attackers. 7) Educate DevOps and security teams about the risks of user enumeration and the importance of secure authentication design in container management platforms.
Affected Countries
United States, Germany, United Kingdom, Canada, Australia, Japan, Netherlands
CVE-2024-29296: n/a
Description
A user enumeration vulnerability was found in Portainer CE 2.19.4. This issue occurs during user authentication process, where a difference in response time could allow a remote unauthenticated user to determine if a username is valid or not.
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2024-29296 identifies a user enumeration vulnerability in Portainer Community Edition (CE) version 2.19.4. The flaw arises during the user authentication process, where the application responds with different timing delays depending on whether a submitted username exists or not. This timing discrepancy can be remotely observed by an unauthenticated attacker, enabling them to confirm the validity of usernames without needing credentials or user interaction. The vulnerability is classified under CWE-286 (Improper Authorization), as it leaks information that should be protected. The CVSS v3.1 base score is 5.3, reflecting a medium severity impact primarily on confidentiality. The vulnerability does not affect the integrity or availability of the system. No patches or fixes are currently linked, and no known exploits have been reported in the wild. However, the ability to enumerate valid usernames can significantly aid attackers in crafting targeted attacks such as password guessing, brute force, or social engineering campaigns. Portainer CE is a widely used open-source container management platform that simplifies Docker and Kubernetes management, making this vulnerability relevant to organizations leveraging containerized environments. The issue highlights the importance of consistent response times and error messages during authentication to prevent side-channel information leaks.
Potential Impact
The primary impact of CVE-2024-29296 is the compromise of confidentiality through user enumeration. Attackers can remotely identify valid usernames on Portainer CE instances without authentication, which can be leveraged to facilitate further attacks such as brute force password attempts, credential stuffing, or targeted phishing campaigns. Although the vulnerability does not directly affect system integrity or availability, the exposure of valid user accounts increases the attack surface and risk of unauthorized access if combined with other vulnerabilities or weak credentials. Organizations relying on Portainer CE for container management may face increased risk of account compromise, potentially leading to unauthorized container deployments, data exposure, or lateral movement within infrastructure. The medium CVSS score reflects that while exploitation is relatively straightforward and impactful for reconnaissance, it does not directly cause system disruption or data modification. The absence of known exploits in the wild suggests limited immediate threat, but the vulnerability should be addressed proactively to prevent future exploitation.
Mitigation Recommendations
To mitigate CVE-2024-29296, organizations should: 1) Monitor Portainer CE vendor communications closely and apply security patches or updates promptly once available to address the timing discrepancy. 2) Implement uniform response times and error messages during authentication processes to eliminate timing side channels that reveal username validity. This can be achieved by introducing artificial delays or consistent error handling regardless of username correctness. 3) Employ multi-factor authentication (MFA) on Portainer CE accounts to reduce the risk of account compromise even if usernames are enumerated. 4) Enforce strong password policies and consider account lockout or throttling mechanisms after repeated failed login attempts to hinder brute force attacks. 5) Monitor authentication logs for unusual patterns indicative of enumeration or brute force attempts and respond with incident handling procedures. 6) Restrict access to Portainer CE management interfaces to trusted networks or VPNs to reduce exposure to unauthenticated remote attackers. 7) Educate DevOps and security teams about the risks of user enumeration and the importance of secure authentication design in container management platforms.
Affected Countries
Technical Details
- Data Version
- 5.1
- Assigner Short Name
- mitre
- Date Reserved
- 2024-03-19T00:00:00.000Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 699f6d9bb7ef31ef0b5894ae
Added to database: 2/25/2026, 9:46:03 PM
Last enriched: 2/28/2026, 10:32:14 AM
Last updated: 4/12/2026, 3:35:34 PM
Views: 7
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.