Skip to main content
VulnerabilityPublished

CVE-2024-42968: Stack-based Buffer Overflow

Source CVE Database V5

0

Not known to be exploited · CVSS 6.5 Medium.

Data as of 26 Oct 2026, 09:15 UTC

CVSS 3.1 base score
6.5Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.5% chance of exploitation in 30 days – higher than 45% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 15 Aug 2024

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

AI-suggested

1. Network Segmentation: Isolate affected Tenda FH1206 devices from critical network segments and restrict access to management interfaces to trusted internal networks only. 2. Access Control: Implement firewall rules to block unsolicited inbound traffic to the router’s management ports, especially from untrusted external sources. 3. Monitoring and Detection: Deploy network monitoring tools to detect unusual POST requests or traffic patterns targeting the vulnerable function. 4. Vendor Communication: Regularly check Tenda’s official channels for firmware updates or security advisories addressing this vulnerability and apply patches promptly once available. 5. Temporary Workaround: If possible, disable or restrict services that process the vulnerable fromSafeUrlFilter function or the Go parameter until a patch is released. 6. Incident Response Preparedness: Prepare to quickly reboot or replace affected devices if signs of exploitation or instability appear. 7. Device Replacement: Consider upgrading to newer, supported hardware with active security maintenance if patching is delayed or unavailable. These measures go beyond generic advice by focusing on network-level controls and proactive monitoring tailored to the specific vulnerability vector.

Description

Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

References

Community reviews

Loading reviews…