Skip to main content
VulnerabilityPublished Updated

CVE-2024-44760: SunmoEMS · Incorrect Default Permissions

Affects SunmoEMSSource CVE Database V5

0

Not known to be exploited · CVSS 9.1 Critical.

Data as of 26 Oct 2026, 17:16 UTC

CVSS 3.1 base score
9.1Critical
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.5% chance of exploitation in 30 days – higher than 43% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 28 Aug 2024

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
GitHubwarmbrew/SunmoEMSpkg:github/warmbrew/SunmoEMSOther threatsAffected
  • >=5.0 <=18.8
Fixed in–

Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.

AI-suggested

To mitigate CVE-2024-44760, organizations should immediately audit and restrict access to the /servlet/SnoopServlet endpoint. Network-level controls such as firewall rules or web application firewalls (WAFs) should be configured to block external access to this servlet unless explicitly required and secured. If possible, disable or remove the SnoopServlet component entirely if it is not needed for business operations. Conduct thorough access control reviews to ensure that sensitive endpoints are not exposed without proper authentication and authorization. Monitor logs for any suspicious access attempts to this servlet. Additionally, implement network segmentation to isolate critical management systems and reduce exposure. Employ intrusion detection systems (IDS) to detect anomalous activity targeting this vulnerability. Finally, maintain up-to-date backups and incident response plans to prepare for potential exploitation scenarios.

Description

Incorrect access control in the component /servlet/SnoopServlet of Shenzhou News Union Enterprise Management System v5.0 through v18.8 allows attackers to access sensitive information regarding the server.