CVE-2024-45526: UA-.NETStandard · Unthrottled Resource Allocation
Affects UA-.NETStandardSource CVE Database V5
Not known to be exploited · CVSS 5.3 Medium.
Data as of 26 Oct 2026, 17:16 UTC
- EPSS
- 0.5% chance of exploitation in 30 days – higher than 42% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:LExploitation evidence
Disclosed: evidence found.
CVE published 22 Oct 2024
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
GitHubopcfoundation/UA-.NETStandardpkg:github/opcfoundation/UA-.NETStandardOther threats | Affected
| Fixed in– |
Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.
AI-suggested
- Monitor OPC UA server logs for repeated authentication failures or unusual request patterns that may indicate exploitation attempts.
- Implement network-level protections such as firewalls and intrusion detection/prevention systems (IDS/IPS) to limit access to OPC UA servers only to trusted sources.
- Employ rate limiting or connection throttling on OPC UA endpoints to reduce the impact of repeated invalid authentication requests.
- Segment industrial control networks to isolate OPC UA servers from general enterprise networks and the internet, minimizing exposure.
- Stay informed about updates from the OPC Foundation and apply security patches or library updates promptly once they are released.
- Conduct regular security assessments and penetration testing focused on industrial communication protocols to identify and remediate similar resource exhaustion vulnerabilities.
- Consider deploying anomaly detection solutions tailored for industrial protocols to detect early signs of denial-of-service attacks.
Description
An issue was discovered in OPC Foundation OPCFoundation/UA-.NETStandard through 1.5.374.78. A remote attacker can send requests with invalid credentials and cause the server performance to degrade gradually.