Skip to main content
VulnerabilityPublished Updated

CVE-2024-51074: Incorrect Access Control

Source CVE Database V5

0

Not known to be exploited · CVSS 6.7 Medium.

Data as of 26 Oct 2026, 17:16 UTC

CVSS 3.1 base score
6.7Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 19% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 22 Nov 2024

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

AI-suggested

To mitigate this vulnerability, organizations and vehicle owners should ensure that physical access to the vehicle's CAN bus is strictly controlled and monitored. Automotive service centers and fleet operators should implement secure diagnostic procedures that restrict unauthorized access to the instrument cluster and CAN network. Manufacturers should consider firmware updates that enforce stricter access controls on odometer modification commands, including authentication and integrity checks aligned with the UDS protocol. Deployment of intrusion detection systems (IDS) for in-vehicle networks can help detect anomalous CAN messages indicative of tampering attempts. Additionally, integrating cryptographic protections and secure boot mechanisms in ECUs can prevent unauthorized firmware or message injection. Regular audits and inspections of vehicle instrument clusters and odometer readings can help detect inconsistencies early. Collaboration with suppliers to validate test environments and ensure realistic security assessments is also recommended to avoid false positives or underestimations of risk.

Description

Incorrect access control in KIA Seltos vehicle instrument cluster with software and hardware v1.0 allows attackers to arbitrarily change odometer readings in the vehicle by targeting the instrument cluster through the unsecured CAN network. NOTE: this is disputed by the supplier because the CAN bus is not externally exposed, and because the packets can only increase the odometer reading (which typically has no value to an adversary). Also, this is disputed by the Supplier because the findings came from a potentially unrealistic test environment (an isolated ECU part that was not in a vehicle), and because the observed behavior follows the UDS (Unified Diagnostic Services) specification.

References

Community reviews