CVE-2024-54017: Siemens SIPROTEC 5 6MD84 (CP300) · Small Space of Random Values
Affects Siemens SIPROTEC 5 6MD84 (CP300)Source CVE Database V5
Not known to be exploited · CVSS 5.3 Medium : upgrade to 11.0 when convenient.
Data as of 30 Oct 2026, 06:59 UTC
- EPSS
- 0.3% chance of exploitation in 30 days – higher than 23% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in 11.0
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:NExploitation evidence
Disclosed: evidence found.
CVE published 12 May 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 29 Oct 2026.
What to do
Upgrade SIPROTEC 5 to 11.0.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| SiemensSIPROTEC 5 6MD84 (CP300) | Affected
| Fixed in
|
| SiemensSIPROTEC 5 6MD85 (CP300) | Affected
| Fixed in
|
| SiemensSIPROTEC 5 6MD86 (CP300) | Affected
| Fixed in
|
| SiemensSIPROTEC 5 6MD89 (CP300) | Affected
| Fixed in
|
| SiemensSIPROTEC 5 6MU85 (CP300) | Affected
| Fixed in
|
| SiemensSIPROTEC 5 7KE85 (CP300) | Affected
| Fixed in
|
AI-suggested
If you cannot patch yet, consider restricting network access to the affected devices' web interfaces to trusted users only to reduce exposure.
Description
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). Affected devices do not use sufficiently random values to create session identifiers. This could allow an unauthenticated remote attacker to brute force a session identifier and gain read access to limited information from the web server without authorization.