CVE-2024-9147: CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) in Bna Informatics PosPratik
CVE-2024-9147 is a medium severity vulnerability in Bna Informatics PosPratik before version 3. 2. 1. It involves improper neutralization of script-related HTML tags, resulting in a basic cross-site scripting (XSS) vulnerability exploitable via HTTP query strings. This flaw allows an attacker to inject malicious scripts that may be executed in the context of the affected web application. No official patch or remediation guidance is currently confirmed. The vulnerability does not require user interaction or privileges to exploit but has limited impact on confidentiality and availability. There are no known exploits in the wild at this time.
AI Analysis
Technical Summary
The vulnerability identified as CVE-2024-9147 affects Bna Informatics PosPratik versions prior to 3.2.1. It is categorized as CWE-80, indicating improper neutralization of script-related HTML tags in a web page, leading to a basic cross-site scripting (XSS) vulnerability. This issue allows attackers to inject malicious scripts through HTTP query strings, potentially enabling script execution in users' browsers. The CVSS 4.0 base score is 6.9, reflecting network attack vector, low attack complexity, no privileges or user interaction required, and limited impact on confidentiality and availability. No patch or official remediation level has been published by the vendor, and the product is not a cloud service. No known exploits have been reported.
Potential Impact
Successful exploitation of this vulnerability could allow an attacker to execute arbitrary scripts in the context of the affected web application, potentially leading to limited confidentiality and availability impacts. The CVSS vector indicates no impact on integrity or system control, and the attack does not require user interaction or privileges. There are no known exploits in the wild, suggesting limited active threat at this time.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Since no official fix or remediation level is provided, users of Bna Informatics PosPratik should monitor vendor communications for updates. Until a patch is available, consider applying input validation or output encoding on HTTP query strings to mitigate XSS risks if feasible.
CVE-2024-9147: CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) in Bna Informatics PosPratik
Description
CVE-2024-9147 is a medium severity vulnerability in Bna Informatics PosPratik before version 3. 2. 1. It involves improper neutralization of script-related HTML tags, resulting in a basic cross-site scripting (XSS) vulnerability exploitable via HTTP query strings. This flaw allows an attacker to inject malicious scripts that may be executed in the context of the affected web application. No official patch or remediation guidance is currently confirmed. The vulnerability does not require user interaction or privileges to exploit but has limited impact on confidentiality and availability. There are no known exploits in the wild at this time.
CVSS v4.0
Score 6.9medium
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
The vulnerability identified as CVE-2024-9147 affects Bna Informatics PosPratik versions prior to 3.2.1. It is categorized as CWE-80, indicating improper neutralization of script-related HTML tags in a web page, leading to a basic cross-site scripting (XSS) vulnerability. This issue allows attackers to inject malicious scripts through HTTP query strings, potentially enabling script execution in users' browsers. The CVSS 4.0 base score is 6.9, reflecting network attack vector, low attack complexity, no privileges or user interaction required, and limited impact on confidentiality and availability. No patch or official remediation level has been published by the vendor, and the product is not a cloud service. No known exploits have been reported.
Potential Impact
Successful exploitation of this vulnerability could allow an attacker to execute arbitrary scripts in the context of the affected web application, potentially leading to limited confidentiality and availability impacts. The CVSS vector indicates no impact on integrity or system control, and the attack does not require user interaction or privileges. There are no known exploits in the wild, suggesting limited active threat at this time.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Since no official fix or remediation level is provided, users of Bna Informatics PosPratik should monitor vendor communications for updates. Until a patch is available, consider applying input validation or output encoding on HTTP query strings to mitigate XSS risks if feasible.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- TR-CERT
- Date Reserved
- 2024-09-24T12:44:48.977Z
- Cvss Version
- 4.0
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a1e956ce29bf47b50adc061
Added to database: 6/2/2026, 8:33:48 AM
Last enriched: 6/2/2026, 8:49:13 AM
Last updated: 6/2/2026, 9:40:34 AM
Views: 3
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.