Skip to main content
EPSS 0.3%top 77%

CVE-2025-12768: CWE-787 Out-of-bounds write in Rockwell Automation FactoryTalk® Historian Machine Edition

0
High
VulnerabilityCVE-2025-12768cvecve-2025-12768cwe-787
Published: 09/01/2026 (09/01/2026, 13:40:50 UTC)
Source: CVE Database V5
Vendor/Project: Rockwell Automation
Product: FactoryTalk® Historian Machine Edition

Description

A security issue exists within FactoryTalk® Historian Machine Edition. An attacker with low-level authentication could exploit this vulnerability to achieve remote code execution on the affected device.

CVSS v4.0

Score 8.6high

Attack Vector
Adjacent Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vuln. Confidentiality
High
Vuln. Integrity
High
Vuln. Availability
High
Subsq. Confidentiality
None
Subsq. Integrity
None
Subsq. Availability
None
CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Affected software

Rockwell Automation

FactoryTalk® Historian Machine Edition

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 09/07/2026, 14:00:05 UTC

Technical Analysis

This vulnerability in FactoryTalk® Historian Machine Edition is caused by an out-of-bounds write condition (CWE-787). An attacker with low-level authentication privileges can exploit this flaw to execute arbitrary code remotely on the targeted system. The CVSS 4.0 base score is 8.6, reflecting the attack vector as adjacent network, low attack complexity, no user interaction, and high impact on confidentiality, integrity, and availability. The vendor has not published any remediation or patch information, and the affected versions are not explicitly stated.

Potential Impact

Successful exploitation allows remote code execution by an attacker with low-level authentication, potentially compromising the confidentiality, integrity, and availability of the affected system. This could lead to unauthorized control over the device running FactoryTalk® Historian Machine Edition.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict access to the affected system to trusted users only and monitor for suspicious activity involving low-level authenticated users.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
Rockwell
Date Reserved
2025-11-05T19:12:12.688Z
Cvss Version
4.0
State
PUBLISHED

Threat ID: 6a96d8afacd9273b49c6bf34

Added to database: 09/01/2026, 13:52:47 UTC

Last enriched: 09/07/2026, 14:00:05 UTC

Last updated: 10/15/2026, 18:48:12 UTC

Views: 81

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses