CVE-2025-22906: n/a
RE11S v1.11 was discovered to contain a command injection vulnerability via the L2TPUserName parameter at /goform/setWAN.
AI Analysis
Technical Summary
CVE-2025-22906 identifies a command injection vulnerability in RE11S v1.11. The issue arises from improper input handling of the L2TPUserName parameter at the /goform/setWAN endpoint, enabling remote attackers to execute arbitrary commands without authentication. The vulnerability has a CVSS 3.1 base score of 9.8, reflecting its critical severity and potential for full system compromise. No vendor advisory or patch information is available at this time, and no known exploits have been reported in the wild.
Potential Impact
Successful exploitation can lead to full compromise of the affected system, including unauthorized command execution, complete loss of confidentiality, integrity, and availability. Given the unauthenticated nature of the vulnerability, attackers can remotely execute arbitrary commands without prior access.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict access to the affected endpoint and monitor for suspicious activity related to the /goform/setWAN interface. Avoid exposing the vulnerable service to untrusted networks.
CVE-2025-22906: n/a
Description
RE11S v1.11 was discovered to contain a command injection vulnerability via the L2TPUserName parameter at /goform/setWAN.
CVSS v3.1
Score 9.8critical
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2025-22906 identifies a command injection vulnerability in RE11S v1.11. The issue arises from improper input handling of the L2TPUserName parameter at the /goform/setWAN endpoint, enabling remote attackers to execute arbitrary commands without authentication. The vulnerability has a CVSS 3.1 base score of 9.8, reflecting its critical severity and potential for full system compromise. No vendor advisory or patch information is available at this time, and no known exploits have been reported in the wild.
Potential Impact
Successful exploitation can lead to full compromise of the affected system, including unauthorized command execution, complete loss of confidentiality, integrity, and availability. Given the unauthenticated nature of the vulnerability, attackers can remotely execute arbitrary commands without prior access.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is available, restrict access to the affected endpoint and monitor for suspicious activity related to the /goform/setWAN interface. Avoid exposing the vulnerable service to untrusted networks.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- mitre
- Date Reserved
- 2025-01-09T00:00:00.000Z
- Cvss Version
- 3.1
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a49b1d427e9c79719a8ab41
Added to database: 07/05/2026, 01:22:28 UTC
Last enriched: 07/12/2026, 08:40:26 UTC
Last updated: 07/27/2026, 20:51:59 UTC
Views: 16
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.