Skip to main content
Press slash or control plus K to focus the search. Use the arrow keys to navigate results and press enter to open a threat.
Reconnecting to live updates…

CVE-2025-27013: Missing Authorization in QuanticaLabs MediCenter - Health Medical Clinic

0
Unknown
VulnerabilityCVE-2025-27013cvecve-2025-27013
Published: Tue Feb 18 2025 (02/18/2025, 19:53:35 UTC)
Source: CVE Database V5
Vendor/Project: QuanticaLabs
Product: MediCenter - Health Medical Clinic

Description

Missing Authorization vulnerability in QuanticaLabs MediCenter - Health Medical Clinic medicenter allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects MediCenter - Health Medical Clinic: from n/a through < 14.7.

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 04/01/2026, 23:00:38 UTC

Technical Analysis

CVE-2025-27013 identifies a missing authorization vulnerability in the QuanticaLabs MediCenter - Health Medical Clinic software, affecting versions prior to 14.7. The vulnerability arises from incorrectly configured access control security levels, which means that certain functions or data that should be restricted are accessible without proper authorization checks. This can allow an attacker to bypass security controls and gain unauthorized access to sensitive patient data or administrative features within the healthcare management system. The vulnerability is classified as an access control flaw, which is critical in healthcare environments where patient confidentiality and data integrity are paramount. Although no known exploits have been reported in the wild, the flaw’s presence in a widely used healthcare product poses a significant risk. The lack of a CVSS score indicates that the vulnerability is newly disclosed and pending further assessment. The issue affects all versions before 14.7, and the vendor has not yet published patches or mitigation details. Given the nature of the vulnerability, attackers with network access to the system could exploit this flaw without requiring user interaction or authentication, depending on the deployment context. This vulnerability highlights the importance of rigorous access control implementation in healthcare software to prevent unauthorized data exposure or modification.

Potential Impact

The potential impact of CVE-2025-27013 is significant for healthcare organizations worldwide. Unauthorized access to medical clinic management software can lead to exposure of sensitive patient health information, violating privacy regulations such as HIPAA in the United States or GDPR in Europe. Attackers could manipulate patient records, disrupt clinical workflows, or gain administrative privileges to further compromise the system. This could result in loss of patient trust, legal penalties, and operational disruptions. The integrity and availability of critical healthcare data may also be at risk if attackers modify or delete records. Since healthcare systems are often interconnected with other hospital infrastructure, exploitation could have cascading effects. The absence of known exploits currently limits immediate widespread impact, but the vulnerability’s nature makes it a prime target for attackers once exploit code becomes available. Organizations using MediCenter software should consider this a high-risk issue requiring urgent attention.

Mitigation Recommendations

Organizations should immediately inventory their deployments of QuanticaLabs MediCenter - Health Medical Clinic software to identify affected versions prior to 14.7. Until an official patch is released, administrators should review and tighten access control configurations, ensuring that only authorized personnel have access to sensitive functions and data. Network segmentation and strict firewall rules should be applied to limit access to the MediCenter system from untrusted networks. Implementing strong authentication mechanisms and monitoring access logs for unusual activity can help detect potential exploitation attempts. Organizations should subscribe to vendor advisories and apply patches promptly once available. Additionally, conducting security audits and penetration testing focused on access control can help identify and remediate similar weaknesses. Employee training on recognizing suspicious activity and incident response readiness will further reduce risk.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
Patchstack
Date Reserved
2025-02-17T11:52:15.090Z
Cvss Version
null
State
PUBLISHED

Threat ID: 69cd72c4e6bfc5ba1deecd47

Added to database: 4/1/2026, 7:32:20 PM

Last enriched: 4/1/2026, 11:00:38 PM

Last updated: 4/6/2026, 9:22:14 AM

Views: 2

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses