CVE-2025-32992: Thermo Fisher Scientific ePort · Improper Access Control
Source CVE Database V5
Not known to be exploited · CVSS 8.5 High · fixed in 3.0.1 : patch affected systems soon.
Data as of 26 Oct 2026, 13:47 UTC
- EPSS
- 0.2% chance of exploitation in 30 days – higher than 12% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in 3.0.1
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:H/A:NExploitation evidence
Disclosed: evidence found.
CVE published 18 Aug 2025
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
AI-suggested
In the absence of an official patch, European organizations should immediately conduct a thorough access control audit of their ePort deployments. This includes reviewing user roles and permissions to ensure the principle of least privilege is enforced, disabling or restricting access for non-essential users, and monitoring access logs for unusual activity. Network segmentation should be implemented to isolate the ePort system from less trusted networks and limit exposure. Employing multi-factor authentication (MFA) where possible can add an additional layer of security. Organizations should also engage with Thermo Fisher Scientific for updates on patch availability and apply any vendor-recommended mitigations promptly. Implementing intrusion detection and prevention systems (IDPS) focused on detecting anomalous access patterns to the ePort system can help identify exploitation attempts early. Finally, organizations should prepare incident response plans specific to this vulnerability, including data backup and recovery procedures to mitigate potential data integrity issues.
Description
Thermo Fisher Scientific ePort through 3.0.0 has Incorrect Access Control.