Skip to main content
VulnerabilityPublished

CVE-2025-41669: Phoenix Contact AXC F 1152 · Improper Verification of Cryptographic Signature

Affects Phoenix Contact AXC F 1152Source CVE Database V5

0
Compare

Not known to be exploited · CVSS 8.7 High : upgrade to 2026.0.3 soon.

Data as of 30 Oct 2026, 11:52 UTC

CVSS 4.0 base score
8.7High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 12% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
Patch
Available – fixed in 2026.0.3
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 27 May 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 30 Oct 2026.

What to do

Upgrade AXC F 1152 and AXC F 1252 and AXC F 2000 EA and AXC F 2152 and AXC F 3152 and BPC 9102S and EPC 1522 and RFC 4072R and RFC 4072S and VL3 UPC 2440 EDGE and VPLCNEXT CONTROL 1000 and VPLCNEXT CONTROL 2000 and VPLCNEXT CONTROL 3000 and VPLCNEXT CONTROL 500 to 2026.0.3.

Affected software

ProductAffectedFixed in
Phoenix ContactAXC F 1152Affected
  • <2026.0.3
Fixed in
  • 2026.0.3
Phoenix ContactAXC F 1252Affected
  • <2026.0.3
Fixed in
  • 2026.0.3
Phoenix ContactAXC F 2000 EAAffected
  • <2026.0.3
Fixed in
  • 2026.0.3
Phoenix ContactAXC F 2152Affected
  • <2026.0.3
Fixed in
  • 2026.0.3
Phoenix ContactAXC F 3152Affected
  • <2026.0.3
Fixed in
  • 2026.0.3
Phoenix ContactBPC 9102SAffected
  • <2026.0.3
Fixed in
  • 2026.0.3

AI-suggested

If you cannot patch yet, restrict Engineer user privileges and limit access to the Web-based Management interface to trusted personnel only. Monitor for any unusual app installations or behavior on the device.

Description

The Web-based Management allows a remote low privileged Engineer user to install additional APPs on the device downloaded from the PLCnext Store without implementing any data verification mechanism, leading to the capability for an Engineer user to reach arbitrary code execution with root privileges on the PLC device. A successful exploitation may allow to install a manipulated APP package, potentially impacting integrity and availability of the PLCnext Control.