CVE-2025-43506: iCloud Private Relay may not activate when more than one user is logged in at the same time in Apple macOS
A logic error was addressed with improved error handling. This issue is fixed in macOS Tahoe 26.1. iCloud Private Relay may not activate when more than one user is logged in at the same time.
AI Analysis
Technical Summary
CVE-2025-43506 is a logic error vulnerability in Apple macOS's iCloud Private Relay feature, identified as CWE-843 (Access of Resource Using Incompatible Type). The issue arises when more than one user is logged into the same macOS system concurrently, causing iCloud Private Relay to fail to activate properly. iCloud Private Relay is designed to enhance user privacy by routing internet traffic through multiple relays to mask IP addresses and browsing activity. The failure to activate means that user traffic may be exposed to network observers, undermining confidentiality protections. The vulnerability has a CVSS v3.1 base score of 7.5, reflecting its high impact on confidentiality without affecting integrity or availability. It requires no privileges or user interaction to exploit and can be triggered remotely over the network. The flaw was addressed by Apple in macOS Tahoe 26.1 through improved error handling to ensure Private Relay activates correctly in multi-user scenarios. No public exploit code or active exploitation has been reported to date, but the vulnerability poses a significant privacy risk, especially in environments where multiple users share a single macOS device, such as corporate or educational settings. The absence of patch links in the provided data suggests users should rely on official Apple updates and advisories to remediate the issue.
Potential Impact
The primary impact of CVE-2025-43506 is the potential exposure of user internet traffic that would normally be protected by iCloud Private Relay, leading to a loss of confidentiality. This can allow network attackers or observers to monitor browsing activity, IP addresses, and potentially infer user behavior or location. For organizations, this undermines privacy guarantees and may violate compliance requirements related to data protection. The vulnerability does not affect data integrity or system availability, but the privacy implications are significant, especially for sensitive or regulated environments. Multi-user macOS systems, such as shared workstations, labs, or kiosks, are at higher risk because the flaw manifests specifically when multiple users are logged in simultaneously. The ease of exploitation without authentication or user interaction increases the threat level, as attackers can potentially trigger the failure remotely. Although no known exploits exist currently, the vulnerability's characteristics make it a likely target for future attacks aiming to bypass privacy protections.
Mitigation Recommendations
To mitigate CVE-2025-43506, organizations and users should promptly update all affected macOS systems to version Tahoe 26.1 or later, where the issue is fixed. For environments where immediate patching is not feasible, consider limiting concurrent multi-user logins on macOS devices to prevent the condition that triggers the vulnerability. Network monitoring should be enhanced to detect unusual traffic patterns that might indicate Private Relay failures or attempts to exploit this flaw. Additionally, educate users about the importance of logging out of shared devices when not in use to reduce exposure. IT administrators should review device usage policies to minimize shared access and consider deploying endpoint protection solutions capable of detecting anomalous network activity. Finally, maintain awareness of Apple security advisories for any updates or additional mitigations related to this vulnerability.
Affected Countries
United States, Canada, United Kingdom, Germany, France, Australia, Japan, South Korea, Singapore, Sweden, Netherlands
CVE-2025-43506: iCloud Private Relay may not activate when more than one user is logged in at the same time in Apple macOS
Description
A logic error was addressed with improved error handling. This issue is fixed in macOS Tahoe 26.1. iCloud Private Relay may not activate when more than one user is logged in at the same time.
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2025-43506 is a logic error vulnerability in Apple macOS's iCloud Private Relay feature, identified as CWE-843 (Access of Resource Using Incompatible Type). The issue arises when more than one user is logged into the same macOS system concurrently, causing iCloud Private Relay to fail to activate properly. iCloud Private Relay is designed to enhance user privacy by routing internet traffic through multiple relays to mask IP addresses and browsing activity. The failure to activate means that user traffic may be exposed to network observers, undermining confidentiality protections. The vulnerability has a CVSS v3.1 base score of 7.5, reflecting its high impact on confidentiality without affecting integrity or availability. It requires no privileges or user interaction to exploit and can be triggered remotely over the network. The flaw was addressed by Apple in macOS Tahoe 26.1 through improved error handling to ensure Private Relay activates correctly in multi-user scenarios. No public exploit code or active exploitation has been reported to date, but the vulnerability poses a significant privacy risk, especially in environments where multiple users share a single macOS device, such as corporate or educational settings. The absence of patch links in the provided data suggests users should rely on official Apple updates and advisories to remediate the issue.
Potential Impact
The primary impact of CVE-2025-43506 is the potential exposure of user internet traffic that would normally be protected by iCloud Private Relay, leading to a loss of confidentiality. This can allow network attackers or observers to monitor browsing activity, IP addresses, and potentially infer user behavior or location. For organizations, this undermines privacy guarantees and may violate compliance requirements related to data protection. The vulnerability does not affect data integrity or system availability, but the privacy implications are significant, especially for sensitive or regulated environments. Multi-user macOS systems, such as shared workstations, labs, or kiosks, are at higher risk because the flaw manifests specifically when multiple users are logged in simultaneously. The ease of exploitation without authentication or user interaction increases the threat level, as attackers can potentially trigger the failure remotely. Although no known exploits exist currently, the vulnerability's characteristics make it a likely target for future attacks aiming to bypass privacy protections.
Mitigation Recommendations
To mitigate CVE-2025-43506, organizations and users should promptly update all affected macOS systems to version Tahoe 26.1 or later, where the issue is fixed. For environments where immediate patching is not feasible, consider limiting concurrent multi-user logins on macOS devices to prevent the condition that triggers the vulnerability. Network monitoring should be enhanced to detect unusual traffic patterns that might indicate Private Relay failures or attempts to exploit this flaw. Additionally, educate users about the importance of logging out of shared devices when not in use to reduce exposure. IT administrators should review device usage policies to minimize shared access and consider deploying endpoint protection solutions capable of detecting anomalous network activity. Finally, maintain awareness of Apple security advisories for any updates or additional mitigations related to this vulnerability.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- apple
- Date Reserved
- 2025-04-16T15:27:21.194Z
- Cvss Version
- null
- State
- PUBLISHED
Threat ID: 693c857df55ccbd2c799d36f
Added to database: 12/12/2025, 9:13:33 PM
Last enriched: 4/3/2026, 2:33:17 AM
Last updated: 5/10/2026, 12:30:27 AM
Views: 143
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.