Skip to main content
VulnerabilityPublished Updated

CVE-2025-52264: CVEs · Memory Buffer Overflow

Affects CVEsSource CVE Database V5

0

Not known to be exploited · CVSS 8.0 High.

Data as of 26 Oct 2026, 11:07 UTC

CVSS 3.1 base score
8.0High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 21% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 27 Oct 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

Affected software

ProductAffectedFixed in
GitHubhatoan/CVEspkg:github/hatoan/CVEsOther threatsAffected
  • =1.0.4
Fixed in–

Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.

AI-suggested

  1. Immediately restrict network access to StarCharge Artemis AC Chargers by implementing strict network segmentation and firewall rules to limit access to trusted administrators and management systems only.
  2. Disable or restrict access to the download.cgi interface if possible, or monitor and log all access attempts to detect suspicious activity.
  3. Employ intrusion detection/prevention systems (IDS/IPS) tuned to detect anomalous traffic patterns or attempts to exploit stack overflow conditions.
  4. Engage with the vendor to obtain timelines for firmware patches or updates addressing this vulnerability and prioritize their deployment once available.
  5. Conduct regular vulnerability assessments and penetration testing focused on EV charging infrastructure to identify and remediate related weaknesses.
  6. Implement strong authentication and authorization controls for device management interfaces to reduce the risk posed by low-privilege attackers.
  7. Maintain up-to-date asset inventories to quickly identify affected devices and ensure rapid response capabilities.
  8. Educate operational technology (OT) and IT teams on the risks associated with this vulnerability and best practices for securing EV charging infrastructure.

Description

StarCharge Artemis AC Charger 7-22 kW v1.0.4 was discovered to contain a stack overflow via the cgiMain function at download.cgi.