CVE-2025-55703: Sunbird Power IQ · CVE-2025-55703 is an error-based SQL injection
Source CVE Database V5
Not known to be exploited · CVSS 2.5 Low · fixed in 9.2.1 : update affected systems when convenient.
Data as of 26 Oct 2026, 09:15 UTC
- EPSS
- 0.1% chance of exploitation in 30 days – higher than 3% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in 9.2.1
CVSS:3.1/AC:H/AV:L/A:N/C:L/I:N/PR:L/S:C/UI:RExploitation evidence
Disclosed: evidence found.
CVE published 15 Dec 2025
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
AI-suggested
European organizations should immediately upgrade Sunbird Power IQ installations from version 9.2.0 to 9.2.1 or later to apply the official fix. In addition, they should audit and restrict API access to trusted users and systems, implementing strict authentication and authorization controls. Employing Web Application Firewalls (WAFs) with SQL injection detection rules can provide an additional defensive layer. Regularly review API logs for unusual or suspicious activity indicative of injection attempts. Conduct security training to ensure users understand the risks of interacting with untrusted inputs. Network segmentation should be applied to isolate management interfaces from general user networks. Finally, integrate vulnerability scanning and penetration testing focused on API endpoints to proactively identify and remediate similar issues before exploitation.
Description
CVE-2025-55703 is an error-based SQL injection vulnerability in the Sunbird Power IQ 9.2.0 API caused by improper input validation on an outdated API endpoint. This flaw allows attackers with low privileges and requiring user interaction to manipulate SQL queries, potentially exposing limited confidential data. The vulnerability has a low CVSS score of 2.5 due to high attack complexity, limited impact on confidentiality, and the need for authentication and user interaction. It was fixed in version 9.2.1 by updating the API call code to safely handle input arrays. No known exploits are currently reported in the wild.