CVE-2025-61197: Client-Side Enforcement of Server-Side Security
Source CVE Database V5
Not known to be exploited · CVSS 8.9 High.
Data as of 26 Oct 2026, 16:39 UTC
- EPSS
- 0.3% chance of exploitation in 30 days – higher than 29% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:LExploitation evidence
Disclosed: evidence found.
CVE published 6 Oct 2025
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
AI-suggested
- Immediately audit all Orban Optimod devices to identify affected versions and assess exposure of web management interfaces.
- Restrict access to device management interfaces to trusted internal networks using network segmentation and firewall rules.
- Disable or limit client-side storage of sensitive information by configuring the application or applying custom security headers (e.g., Content-Security-Policy, HttpOnly cookies) if possible.
- Monitor logs and network traffic for unusual privilege escalation attempts or unauthorized access patterns.
- Engage with Orban support to obtain patches or firmware updates addressing this vulnerability as soon as they become available.
- Implement multi-factor authentication and strong access controls on management interfaces to reduce risk.
- Conduct user training to raise awareness about the risks of client-side data manipulation.
- Consider deploying web application firewalls (WAFs) to detect and block exploitation attempts targeting client-side storage manipulation.
- Regularly review and update security policies related to device management and remote access.
- Prepare incident response plans specifically addressing potential compromise of broadcast equipment.
Description
An issue in Orban Optimod 5950, Optimod 5950HD, Optimod 5750, Optimod 5750HD, Optimod Trio Optimod version 1.0.0.33 - System version 2.5.26 allows a remote attacker to escalate privileges via the application stores user privilege/role information in client-side browser storage