Skip to main content
VulnerabilityPublished Updated

CVE-2025-65231: Barix Instreamer · Cross-site Scripting

Source CVE Database V5

0

Not known to be exploited · CVSS 6.1 Medium.

Data as of 26 Oct 2026, 17:16 UTC

CVSS 3.1 base score
6.1Medium
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.2% chance of exploitation in 30 days – higher than 13% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 8 Dec 2025

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

AI-suggested

To mitigate CVE-2025-65231, European organizations should implement the following specific measures: 1) Restrict access to the Barix Instreamer web interface by network segmentation and firewall rules, allowing only trusted management hosts to connect. 2) Employ strong authentication and ensure that only authorized personnel can access the device’s configuration pages. 3) Monitor and audit web interface logs for unusual input patterns or repeated access to the CTS close command field. 4) If possible, disable or limit the use of the vulnerable CTS close command input field until a vendor patch is available. 5) Use web application firewalls (WAFs) capable of detecting and blocking XSS payloads targeting the device’s web UI. 6) Educate users and administrators about the risks of clicking untrusted links or entering unverified input in device management interfaces. 7) Regularly check for firmware updates or security advisories from Barix and apply patches promptly once released. 8) Consider deploying network intrusion detection systems (NIDS) to detect exploitation attempts targeting the device. These targeted steps go beyond generic advice by focusing on access control, monitoring, and input restriction specific to the vulnerable component.

Description

Barix Instreamer v04.06 and earlier is vulnerable to Cross Site Scripting (XSS) in the Web UI I/O & Serial configuration page, specifically the CTS close command user-input field which is stored and later rendered on the Status page.