Skip to main content
VulnerabilityPublished Updated

CVE-2025-70252: Tenda AC6V2.0 · Stack-based Buffer Overflow

Source CVE Database V5

0

Not known to be exploited · CVSS 7.5 High.

Data as of 26 Oct 2026, 13:47 UTC

CVSS 3.1 base score
7.5High
How severe the flaw is on the 0–10 CVSS scale.
EPSS
0.4% chance of exploitation in 30 days – higher than 40% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 2 Mar 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponised: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.

What to do

AI-suggested

To mitigate CVE-2025-70252, organizations should first check for firmware updates from Tenda addressing this vulnerability and apply them promptly once available. In the absence of an official patch, administrators should disable the WPS feature if it is not essential, as this reduces the attack surface related to the vulnerable endpoint. Restrict access to the router’s management interface by implementing network segmentation and firewall rules to limit access only to trusted internal networks or VPN connections. Monitoring network traffic for unusual requests to /goform/WifiWpsStart can help detect exploitation attempts. Employing intrusion detection/prevention systems (IDS/IPS) with signatures targeting this vulnerability can provide additional defense. Regularly auditing and updating device firmware and configurations will help prevent exploitation of similar vulnerabilities. Finally, consider replacing affected devices with models from vendors with stronger security track records if long-term support is uncertain.

Description

An issue was discovered in /goform/WifiWpsStart in Tenda AC6V2.0 V15.03.06.23_multi. The index and mode are controllable. If the conditions are met to sprintf, they will be spliced into tmp. It is worth noting that there is no size check,which leads to a stack overflow vulnerability.

References

Community reviews

Loading reviews…