CVE-2025-71318: Missing Authentication for Critical Function in Riello UPS NetMan 204
NetMan 204 fails to enforce authentication on its administrative pages and command endpoints. A remote, unauthenticated attacker can directly request administrative pages (such as administration.html, administration-commands.html, and configuration.html) to disclose sensitive information including LDAP configuration and active user details, and can invoke privileged UPS control commands — including shutdown, reboot, switch-on-bypass, and battery test — without supplying any credentials.
AI Analysis
Technical Summary
The Riello UPS NetMan 204 device fails to enforce authentication on its administrative interfaces, including pages like administration.html, administration-commands.html, and configuration.html. This lack of authentication enables a remote, unauthenticated attacker to retrieve sensitive information such as LDAP configuration and active user details. Additionally, the attacker can invoke critical UPS control commands—shutdown, reboot, switch-on-bypass, and battery test—without providing any credentials. The vulnerability is rated critical with a CVSS 4.0 score of 9.3, reflecting its network attack vector, no required privileges or user interaction, and high impact on confidentiality, integrity, and availability. No patch or official remediation level has been published by the vendor as of the provided data.
Potential Impact
An unauthenticated remote attacker can gain access to sensitive administrative information and execute critical control commands on the UPS device, potentially disrupting power management and causing operational outages. The confidentiality, integrity, and availability of the UPS system are all severely impacted. This could lead to unauthorized shutdowns, reboots, or other disruptive actions on the UPS, affecting dependent infrastructure.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Since no official fix or remediation level is provided, users should monitor vendor communications for updates. Until a patch is available, consider restricting network access to the NetMan 204 administrative interfaces to trusted hosts only and implement network-level controls to limit exposure.
CVE-2025-71318: Missing Authentication for Critical Function in Riello UPS NetMan 204
Description
NetMan 204 fails to enforce authentication on its administrative pages and command endpoints. A remote, unauthenticated attacker can directly request administrative pages (such as administration.html, administration-commands.html, and configuration.html) to disclose sensitive information including LDAP configuration and active user details, and can invoke privileged UPS control commands — including shutdown, reboot, switch-on-bypass, and battery test — without supplying any credentials.
CVSS v4.0
Score 9.3critical
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
The Riello UPS NetMan 204 device fails to enforce authentication on its administrative interfaces, including pages like administration.html, administration-commands.html, and configuration.html. This lack of authentication enables a remote, unauthenticated attacker to retrieve sensitive information such as LDAP configuration and active user details. Additionally, the attacker can invoke critical UPS control commands—shutdown, reboot, switch-on-bypass, and battery test—without providing any credentials. The vulnerability is rated critical with a CVSS 4.0 score of 9.3, reflecting its network attack vector, no required privileges or user interaction, and high impact on confidentiality, integrity, and availability. No patch or official remediation level has been published by the vendor as of the provided data.
Potential Impact
An unauthenticated remote attacker can gain access to sensitive administrative information and execute critical control commands on the UPS device, potentially disrupting power management and causing operational outages. The confidentiality, integrity, and availability of the UPS system are all severely impacted. This could lead to unauthorized shutdowns, reboots, or other disruptive actions on the UPS, affecting dependent infrastructure.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Since no official fix or remediation level is provided, users should monitor vendor communications for updates. Until a patch is available, consider restricting network access to the NetMan 204 administrative interfaces to trusted hosts only and implement network-level controls to limit exposure.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- VulnCheck
- Date Reserved
- 2026-06-05T16:56:46.183Z
- Cvss Version
- 4.0
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a23130be29bf47b50a3ecd4
Added to database: 6/5/2026, 6:18:51 PM
Last enriched: 6/5/2026, 6:34:23 PM
Last updated: 6/6/2026, 6:33:42 AM
Views: 8
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.