CVE-2026-0856: Mesalvo Meona Client · Improper Access Control
Affects Mesalvo Meona ClientSource CVE Database V5
Not known to be exploited · CVSS 7.8 High.
Data as of 30 Oct 2026, 11:52 UTC
- EPSS
- 0.1% chance of exploitation in 30 days – higher than 2% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HExploitation evidence
Disclosed: evidence found.
CVE published 20 May 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 30 Oct 2026.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| MesalvoMeona Client | Affected
| Fixed in– |
| MesalvoMeona Server | Affected
| Fixed in– |
AI-suggested
Until a patch is available, restrict local access to trusted users only to reduce risk.
Description
Improper Access Control vulnerability in Mesalvo MEONA (MEONA Client and MEONA Server) allows an authenticated MEONA user to access administrative functions of the MEONA Client (admin panel). The MEONA Server does not independently verify the role asserted by the MEONA Client. A user who holds a valid MEONA user account and is able to execute a modified copy of the MEONA Client on a device within the operating hospital's network can assert an administrator role and access administrative functions with regular user credentials. Exploitation requires: (1) a valid MEONA user account issued by the operating hospital; (2) network access to the MEONA Server, which is operated exclusively within closed hospital networks without exposure to the public Internet (where a hospital permits remote access to that network at all, it is only through the hospital's own remote-access infrastructure (e.g. VPN) under the hospital's control); (3) the ability to modify MEONA Client binaries and to execute the modified copy on a device in that network. On managed devices with application control, as recommended in Mesalvo's hardening guidance (MSA-2026-001), this requires local administrator privileges on the device. Mesalvo is not aware of any exploitation outside the reported security test. This issue affects MEONA Client and MEONA Server in versions 2024.10, 2025.04 and 2026.03. Mitigations are available with MEONA 2025.04.24 and 2026.03.02 (planned Q4 2026); see Mesalvo Security Advisory MSA-2026-001.