Description

An Improper Handling of Length Parameter Inconsistency vulnerability in L2ALM of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated, adjacent attacker to obtain stale PFE packet memory via VXLAN overlay-ping traffic sent to a local VTEP.

CVSS v3.1

Score 4.3medium

Attack Vector
Adjacent Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N

Affected software

Juniper Networks

Junos OS

Affected versions
>=0 <23.2R2-S7.7>=23.4 <23.4R2-S8.13>=24.2 <24.2R2-S5.5>=24.4 <24.4R2-S5>=25.2 <25.2R2-S2>=25.4 <25.4R1-S3>=26.2 <26.2R1-S2

Juniper Networks

Junos OS Evolved

Affected versions
>=0 <23.2R2-S7.7-EVO>=23.4 <23.4R2-S8.11-EVO>=24.2 <24.2R2-S5.6-EVO>=24.4 <24.4R2-S5-EVO>=25.2 <25.2R2-S2-EVO>=25.4 <25.4R1-S3-EVO>=26.2 <26.2R1-S2-EVO>=25.2X100 <25.2X100-D35-EVO>=25.4X300 <25.4X300-D40-EVO=23.4X100
juniper/junos-os
pkg:rpm/juniper/junos-os
Affected versions
<23.2R2-S7.7>=23.4 <23.4R2-S8.13>=24.2 <24.2R2-S5.5>=24.4 <24.4R2-S5>=25.2 <25.2R2-S2>=25.4 <25.4R1-S3>=26.2 <26.2R1-S2
juniper/junos-os-evo
pkg:rpm/juniper/junos-os-evo
Affected versions
<23.2R2-S7.7-EVO>=23.4 <23.4R2-S8.11-EVO>=24.2 <24.2R2-S5.6-EVO>=24.4 <24.4R2-S5-EVO>=25.2 <25.2R2-S2-EVO>=25.4 <25.4R1-S3-EVO>=26.2 <26.2R1-S2-EVO>=25.2X100 <25.2X100-D35-EVO>=25.4X300 <25.4X300-D40-EVO=23.4X100

Run on your own infrastructure? Check whether these packages are installed with threat-finder — our free open-source scanner.

AI-Powered Analysis

Machine-generated threat intelligence

AILast updated: 10/14/2026, 18:19:17 UTC

Technical Analysis

This vulnerability (CVE-2026-102054) in Juniper Networks Junos OS and Junos OS Evolved arises from improper handling of length parameter inconsistencies in the L2ALM module. An unauthenticated attacker with adjacent network access can send VXLAN overlay-ping traffic to a local VTEP, which results in exposure of stale PFE packet memory. The flaw is identified as CWE-130. The CVSS v3.1 base score is 4.3, reflecting low impact on confidentiality and no impact on integrity or availability. The affected versions span multiple release ranges of Junos OS and Junos OS Evolved as explicitly enumerated.

Potential Impact

An unauthenticated adjacent attacker can obtain stale packet memory from the Packet Forwarding Engine (PFE) via VXLAN overlay-ping traffic. The impact is limited to partial confidentiality loss (stale memory disclosure) with no integrity or availability impact. There are no known exploits in the wild. The vulnerability does not allow remote code execution or denial of service.

Mitigation Recommendations

Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. No official fix or patch links are provided in the current data. Until a patch is available, restrict adjacent network access to the affected VXLAN overlay-ping functionality where possible.

Pro Console: star threats, build custom feeds, automate alerts via Slack, email & webhooks.Upgrade to Pro

Technical Details

Data Version
5.2
Assigner Short Name
juniper
Date Reserved
2026-09-28T17:35:40.523Z
Cvss Version
3.1
State
PUBLISHED

Threat ID: 6acfb66b2cdf04f6569794db

Added to database: 10/14/2026, 17:05:47 UTC

Last enriched: 10/14/2026, 18:19:17 UTC

Last updated: 10/14/2026, 21:28:30 UTC

Views: 2

Community Reviews

0 reviews

Crowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.

Sort by
Loading community insights…

Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.

Actions

PRO

Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.

Please log in to the Console to use AI analysis features.

Need more coverage?

Upgrade to Pro Console for AI refresh and higher limits.

For incident response and remediation, OffSeq services can help resolve threats faster.

Latest Threats

Breach by OffSeqOFFSEQFRIENDS — 25% OFF

Check if your credentials are on the dark web

Instant breach scanning across billions of leaked records. Free tier available.

Scan now
OffSeq TrainingCredly Certified

Lead Pen Test Professional

Technical5-day eLearningPECB Accredited
View courses