CVE-2026-102074: CWE-121: Stack-based Buffer Overflow in Siemens APOGEE MBC (PPC) (BACnet)
Description
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The affected product FTP service does not properly validate the length of user-controllable input. This could allow an unauthenticated remote attacker to cause a denial of service.
CVSS v3.1
Score 7.5high
Affected software
Siemens
APOGEE MBC (PPC) (BACnet)
Siemens
APOGEE MBC (PPC) (P2 Ethernet)
Siemens
APOGEE MEC (PPC) (BACnet)
Siemens
APOGEE MEC (PPC) (P2 Ethernet)
Siemens
APOGEE PXC Compact (BACnet)
Siemens
APOGEE PXC Compact (P2 Ethernet)
Siemens
APOGEE PXC Modular (BACnet)
Siemens
APOGEE PXC Modular (P2 Ethernet)
Siemens
TALON TC Compact (BACnet)
Siemens
TALON TC Modular (BACnet)
Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
This vulnerability is a stack-based buffer overflow (CWE-121) in the FTP service of Siemens APOGEE and TALON building automation controllers. The FTP service does not properly validate the length of user-controlled input, enabling an unauthenticated remote attacker to trigger a denial of service by causing a crash or instability. The vulnerability affects multiple product lines and versions, specifically all versions of APOGEE MBC (PPC) (BACnet and P2 Ethernet), APOGEE MEC (PPC) (BACnet and P2 Ethernet), and TALON TC Modular (BACnet), and versions prior to 3.5.7 or 2.8.21 for APOGEE PXC Compact and Modular and TALON TC Compact (BACnet). The CVSS v3.1 base score is 7.5, reflecting network attack vector, low attack complexity, no privileges required, no user interaction, and impact limited to availability (denial of service). No known exploits are reported in the wild. Siemens has not provided explicit patch links or advisories in the input data, and the patch status is not confirmed.
Potential Impact
An unauthenticated remote attacker can exploit this vulnerability to cause a denial of service on affected Siemens APOGEE and TALON devices by sending specially crafted input to the FTP service. This results in service disruption, potentially impacting building automation system availability. There is no reported impact on confidentiality or integrity.
Mitigation Recommendations
Patch status is not yet confirmed — check the Siemens vendor advisory for current remediation guidance. Until a patch is applied, consider restricting network access to the FTP service on affected devices to trusted sources only to reduce exposure. Monitor for unusual FTP traffic patterns that could indicate exploitation attempts.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- siemens
- Date Reserved
- 2026-09-28T17:37:23.337Z
- Cvss Version
- 3.1
- State
- PUBLISHED
Threat ID: 6acdfe992cdf04f6564c8875
Added to database: 10/13/2026, 09:49:13 UTC
Last enriched: 10/13/2026, 10:18:33 UTC
Last updated: 10/13/2026, 18:57:33 UTC
Views: 16
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.