CVE-2026-102700: Xen · cache-flush handling may cause page reference leak in gnttab
Affects XenSource CVE Database V5
Mentioned vulnerabilities
Not known to be exploited · CVSS 4.7 Medium.
Data as of 26 Oct 2026, 14:18 UTC
- EPSS
- 0.1% chance of exploitation in 30 days – higher than 3% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- CISA SSVC
- Exploitation
- No evidence of active exploitation and no public proof of concept
- Automatable
- Attackers cannot reliably automate steps 1–4 of the kill chain
- Technical impact
- Limited control over the software or limited information exposure
CISA SSVC assessment, 2026-10-20.
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:HExploitation evidence
Disclosed: evidence found.
CVE published 13 Oct 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponised: no evidence on record.
No public exploit code indexed in Metasploit or Exploit-DB
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 26 Oct 2026.
What to do
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| XenXen | Affected– | Fixed in– |
Description
With its original introduction, GNTTAB_cache_flush was made available uniformly. XSA-232 (CVE-2017-14318) then covered an omitted NULL pointer check, yet the addition of that check failed to adjust the subsequent error path. That error path fails to drop a page reference in case the specified page is owned by a special system domain (DOM_IO and DOM_COW are system domains which can have memory pages assigned to them.)