CVE-2026-104114: illumos-gate · NULL Pointer Dereference
Affects illumos-gateSource CVE Database V5
Public exploit available · CVSS 5.4 Medium : upgrade to 0f1064d97f1a43778ddf87d4e438b99872aed1a0 as a priority.
Data as of 22 Nov 2026, 21:14 UTC
- EPSS
- 0.1% chance of exploitation in 30 days – higher than 1% of CVEsExploit Prediction Scoring System: the likelihood attackers will use this flaw soon.
- Patch
- Available – fixed in 0f1064d97f1a43778ddf87d4e438b99872aed1a0
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:PExploitation evidence
Disclosed: evidence found.
CVE published 9 Oct 2026
Detectable: no evidence on record.
No public nuclei template indexed
Weaponized: evidence found.
CVSS exploit maturity: proof of concept public
Exploited in the wildExploited: no evidence on record.
Not in CISA KEV and no source reports exploitation
Observed by OffSeq MirageSeen by Mirage: no evidence on record.
No attack traffic recorded by OffSeq Mirage sensors
A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), CVSS vector, the Metasploit, Exploit-DB and nuclei-templates index as of 22 Nov 2026.
What to do
Upgrade illumos-gate to 0f1064d97f1a43778ddf87d4e438b99872aed1a0.
Affected software
| Product | Affected | Fixed in |
|---|---|---|
| illumosillumos-gate | Affected
| Fixed in
|
| OmniOSOmniOS | Affected
| Fixed in– |
Check your own hosts for these packages with threat-finder (opens in a new tab), our free open-source scanner.
AI-suggested
A fix is available in illumos-gate as of commit 0f1064d9. Users should update to a version including this commit to remediate the vulnerability. Note that the nwamd service is not enabled by default; disabling this service if not required can also mitigate exposure.
Description
A NULL pointer dereference in the illumos Network Auto-Magic daemon (nwamd) allows a local user to crash the daemon. nwamd_door_switch() in usr/src/cmd/cmd-inet/lib/nwamd/door_if.c writes to the caller's request structure before checking that a request was supplied, and before checking the caller's credentials. Because the nwamd door at /etc/svc/volatile/nwam/nwam_door is accessible to all local users, an unprivileged user can issue a door_call() with no argument data to crash nwamd; repeated calls place the svc:/network/physical:nwam service into maintenance, stopping automatic network configuration. nwamd runs only when svc:/network/physical:nwam is enabled, which is not the default. The flaw has existed since 2010 (illumos-gate commit 6ba597c5), and affects any illumos distribution prior to illumos-gate commit 0f1064d9.
References
- illumos.topicbox.com/groups/developer/T3b859664594b7762/cve-2026-104112-to-cve-2026-104117-denial-of-service-and-missing-authorization-in-door-servers (opens in a new tab)
- illumos.org/issues/18495 (opens in a new tab)
- github.com/illumos/illumos-gate/commit/0f1064d97f1a43778ddf87d4e438b99872aed1a0 (opens in a new tab)