Skip to main content
VulnerabilityPublished

CVE-2026-118865: TP-Link Systems Archer AX3000 v2 · OS Command Injection

Affects TP-Link Systems Archer AX3000 v2Source CVE Database V5

0
Compare

Not known to be exploited · CVSS 7.3 High : upgrade to 1.1.3 Build 261026 soon.

Data as of 3 Nov 2026, 22:29 UTC

CVSS 4.0 base score
7.3High
How severe the flaw is on the 0–10 CVSS scale.

Thin evidence

One scorer or none
CVSS scores by source
CNA (TPLink)CVSS 4.07.3
Patch
Available – fixed in 1.1.3 Build 261026
CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 3 Nov 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 3 Nov 2026.

What to do

Upgrade TP-Link Systems Archer AX3000 v2 to 1.1.3 Build 261026.

Affected software

ProductAffectedFixed in
TP-Link Systems Inc.Archer AX3000 v2Affected
  • =0
Fixed in
  • 1.1.3 Build 261026

AI-suggested

Apply the official firmware update version 1.1.3 Build 261026 or later provided by TP-Link to remediate this vulnerability. Since a fix is available, upgrading the device firmware is the recommended and effective mitigation. No additional vendor advisories indicate alternative mitigations or that no action is required.

Description

CVE-2026-118865 is an authenticated OS command injection vulnerability in the Offline Download component of TP-Link Archer AX3000 v2 routers. An authenticated administrator attaching a USB storage device can submit a crafted path containing shell metacharacters that are not properly sanitized before being passed to a system command. This flaw allows arbitrary command execution on the affected device. The vulnerability has a CVSS 4.0 score of 7.3 (high severity). A fix is available in firmware version 1.1.3 Build 261026.

References

Community reviews