IBM PowerVM Novalink 2.2.02.2.12.2.1.1, and 2.3.02.3.0.12.3.12.3.2 IBM NovaLink APIs misconfiguration may increase attack surface and enable unintended or unauthorized operations under non-default conditions.
AI Analysis
Technical Summary
CVE-2026-14971 identifies a configuration vulnerability in IBM PowerVM Novalink APIs in versions 2.2.02.2.12.2.1.1 and 2.3.02.3.0.12.3.12.3.2. The misconfiguration could increase the attack surface and enable unintended or unauthorized operations when non-default configurations are used. The vulnerability is categorized as CWE-16, relating to improper configuration. The CVSS v3.1 base score is 3.9 (low), with attack vector local, high attack complexity, high privileges required, no user interaction, unchanged scope, and low impact on confidentiality, integrity, and availability. There is no vendor advisory or patch information available at this time.
Potential Impact
The vulnerability may allow attackers with local access and high privileges to perform unintended or unauthorized operations due to API misconfiguration. The impact on confidentiality, integrity, and availability is low. There are no known exploits in the wild. The risk is limited by the requirement for high privileges and local access, as well as high attack complexity.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix or guidance is provided by IBM, review and harden API configurations to avoid non-default settings that could increase the attack surface. Monitor IBM advisories for updates.
CVE-2026-14971: CWE-16 Configuration in IBM PowerVM Novalink
Description
IBM PowerVM Novalink 2.2.02.2.12.2.1.1, and 2.3.02.3.0.12.3.12.3.2 IBM NovaLink APIs misconfiguration may increase attack surface and enable unintended or unauthorized operations under non-default conditions.
CVSS v3.1
Score 3.9low
Affected software
cpe:2.3:a:ibm:powervm_novalink:2.2.02.2.12.2.1.1:*:*:*:*:*:*:*cpe:2.3:a:ibm:powervm_novalink:2.3.02.3.0.12.3.12.3.2:*:*:*:*:*:*:*Weaknesses
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2026-14971 identifies a configuration vulnerability in IBM PowerVM Novalink APIs in versions 2.2.02.2.12.2.1.1 and 2.3.02.3.0.12.3.12.3.2. The misconfiguration could increase the attack surface and enable unintended or unauthorized operations when non-default configurations are used. The vulnerability is categorized as CWE-16, relating to improper configuration. The CVSS v3.1 base score is 3.9 (low), with attack vector local, high attack complexity, high privileges required, no user interaction, unchanged scope, and low impact on confidentiality, integrity, and availability. There is no vendor advisory or patch information available at this time.
Potential Impact
The vulnerability may allow attackers with local access and high privileges to perform unintended or unauthorized operations due to API misconfiguration. The impact on confidentiality, integrity, and availability is low. There are no known exploits in the wild. The risk is limited by the requirement for high privileges and local access, as well as high attack complexity.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix or guidance is provided by IBM, review and harden API configurations to avoid non-default settings that could increase the attack surface. Monitor IBM advisories for updates.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- ibm
- Date Reserved
- 2026-07-07T16:36:57.998Z
- Cvss Version
- 3.1
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a5b5eaa2d1edb114c7fb1b0
Added to database: 07/18/2026, 11:08:26 UTC
Last enriched: 07/18/2026, 11:50:54 UTC
Last updated: 07/18/2026, 13:34:55 UTC
Views: 2
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.