CVE-2026-18458: CWE-125 Out-of-bounds Read in RTI Connext Professional
Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type ('Type Confusion') vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers. This issue affects Connext Professional: from 7.4.0 before 7.7.0.1, from 7.3.0 before 7.3.1.6, from 6.1.2.21 before 6.1.*.
AI Analysis
Technical Summary
This vulnerability (CVE-2026-18458) in RTI Connext Professional Core Libraries is characterized by an out-of-bounds read caused by a function call with an incorrect number of arguments combined with type confusion. The issue leads to buffer overread, which can result in unauthorized access to memory regions. The affected versions include 6.1.2.21 exactly, all versions from 7.3.0 up to but excluding 7.3.1.6, and all versions from 7.4.0 up to but excluding 7.7.0.1. The CVSS 4.0 base score is 6.8, indicating medium severity, with local attack vector, low attack complexity, no privileges required beyond local, no user interaction, and high impact on availability. There is no information on patches or vendor advisories in the provided data.
Potential Impact
The vulnerability allows an attacker with local access to cause out-of-bounds reads in memory, potentially leading to information disclosure or application instability. The impact is rated medium severity with a CVSS score of 6.8. There are no reports of active exploitation in the wild. The attack requires local privileges and does not require user interaction, limiting the attack surface to local users.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Since no patch or official fix information is provided, users should monitor RTI's advisories for updates. Until a fix is available, limit local access to trusted users and consider applying any recommended workarounds from the vendor once available.
CVE-2026-18458: CWE-125 Out-of-bounds Read in RTI Connext Professional
Description
Out-of-bounds Read, Function Call With Incorrect Number of Arguments, Access of Resource Using Incompatible Type ('Type Confusion') vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers. This issue affects Connext Professional: from 7.4.0 before 7.7.0.1, from 7.3.0 before 7.3.1.6, from 6.1.2.21 before 6.1.*.
CVSS v4.0
Score 6.8medium
Affected software
RTI
Connext Professional
pkg:github/rti/connext-professionalRun on your own infrastructure? Check whether these packages are installed with threat-finder — our free open-source scanner.
AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
This vulnerability (CVE-2026-18458) in RTI Connext Professional Core Libraries is characterized by an out-of-bounds read caused by a function call with an incorrect number of arguments combined with type confusion. The issue leads to buffer overread, which can result in unauthorized access to memory regions. The affected versions include 6.1.2.21 exactly, all versions from 7.3.0 up to but excluding 7.3.1.6, and all versions from 7.4.0 up to but excluding 7.7.0.1. The CVSS 4.0 base score is 6.8, indicating medium severity, with local attack vector, low attack complexity, no privileges required beyond local, no user interaction, and high impact on availability. There is no information on patches or vendor advisories in the provided data.
Potential Impact
The vulnerability allows an attacker with local access to cause out-of-bounds reads in memory, potentially leading to information disclosure or application instability. The impact is rated medium severity with a CVSS score of 6.8. There are no reports of active exploitation in the wild. The attack requires local privileges and does not require user interaction, limiting the attack surface to local users.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Since no patch or official fix information is provided, users should monitor RTI's advisories for updates. Until a fix is available, limit local access to trusted users and consider applying any recommended workarounds from the vendor once available.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- RTI
- Date Reserved
- 2026-07-31T07:29:34.430Z
- Cvss Version
- 4.0
- State
- PUBLISHED
Threat ID: 6ab2c2eff7a7c541068b81d8
Added to database: 09/22/2026, 18:03:27 UTC
Last enriched: 09/22/2026, 18:18:33 UTC
Last updated: 09/23/2026, 01:58:06 UTC
Views: 9
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
External Links
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.