Skip to main content
VulnerabilityPublished

CVE-2026-18768: Beckhoff Automation TcRouter.sys for Windows on x64 3.1.0.2364 · Exposed IOCTL with Insufficient Access Control

Affects Beckhoff Automation TcRouter.sys for Windows on x64 3.1.0.2364Source CVE Database V5

0
Compare

Not known to be exploited · CVSS 8.5 High · fixed in 3.1.0.2365 : patch Beckhoff Automation TcRouter.sys for Windows on x64 3.1.0.2364 soon.

Data as of 11 Nov 2026, 08:36 UTC

CVSS 4.0 base score
8.5High
How severe the flaw is on the 0–10 CVSS scale.

Thin evidence

One scorer or none
CVSS scores by source
CNA (CERTVDE)CVSS 4.08.5
CNA (CERTVDE)CVSS 3.17.8
Patch
Available – fixed in 3.1.0.2365, 3.18.1
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Exploitation evidence

  1. Disclosed: evidence found.

    CVE published 11 Nov 2026

  2. Detectable: no evidence on record.

    No public nuclei template indexed

  3. Weaponized: no evidence on record.

    No public exploit code indexed in Metasploit or Exploit-DB

  4. Exploited in the wild: no evidence on record.

    Not in CISA KEV and no source reports exploitation

  5. Observed by OffSeq Mirage: no evidence on record.

    No attack traffic recorded by OffSeq Mirage sensors

A missing step is not evidence of safety. Sources: cve.org (opens in a new tab), the Metasploit, Exploit-DB and nuclei-templates index as of 10 Nov 2026.

What to do

Upgrade TcRouter.sys for Windows on x64 <3.1.0.2365 and TcRouter.sys for Windows on x86 <3.1.0.2365 to 3.1.0.2365; TwinCAT.XAR.Base.KM <3.18.1 to 3.18.1.

Affected software

ProductAffectedFixed in
Beckhoff AutomationTcRouter.sys for Windows on x64 3.1.0.2364Affected
  • =3.1.0.2364
Fixed in–
Beckhoff AutomationTcRouter.sys for Windows on x64 <3.1.0.2365Affected
  • >=1.0.0 <3.1.0.2365
Fixed in
  • 3.1.0.2365
Beckhoff AutomationTcRouter.sys for Windows on x86 3.1.0.2364Affected
  • =3.1.0.2364
Fixed in–
Beckhoff AutomationTcRouter.sys for Windows on x86 <3.1.0.2365Affected
  • >=1.0.0 <3.1.0.2365
Fixed in
  • 3.1.0.2365
Beckhoff AutomationTwinCAT.XAR.Base.KM 3.16.29Affected
  • =3.16.29
Fixed in–
Beckhoff AutomationTwinCAT.XAR.Base.KM <3.18.1Affected
  • >=1.0.0 <3.18.1
Fixed in
  • 3.18.1

AI-suggested

Fixed versions 3.1.0.2365 and 3.18.1 of TcRouter.sys are available and should be applied to remediate this vulnerability. Users should upgrade to these versions to eliminate the risk. No additional mitigations or workarounds are indicated in the vendor advisory.

Description

CVE-2026-18768 is a high-severity vulnerability in Beckhoff Automation's TcRouter.sys driver for Windows x64. It allows a local low privileged attacker to access arbitrary physical memory or define its mapping due to exposed IOCTL function calls with insufficient access control. This flaw can lead to a full compromise of affected devices. The vulnerability affects versions 1.0.0 up to but not including 3.1.0.2365 and 3.16.29 up to but not including 3.18.1. Fixed versions are 3.1.0.2365 and 3.18.1.

References

Community reviews