CVE-2026-19747: Command Injection in Tenda CH7
A command injection vulnerability exists in multiple Tenda router models including CH7, CH7G, CH10, CP3 series, CP7, and TC3 series up to the build dated 20260625. The flaw is located in the CAte::HandleCmd function within the ATE Module's Kylin file. This vulnerability allows remote attackers to execute arbitrary commands on the affected devices without any authentication. The CVSS 4.0 base score is 9.3, indicating critical severity.
AI Analysis
Technical Summary
CVE-2026-19747 is a critical command injection vulnerability affecting several Tenda router models (CH7, CH7G, CH10, CP3, CP3 Pro, CP7, TC3B14C, TC3B15C, TC3T14C, TC3T15C) up to the 20260625 build. The vulnerability arises from improper input handling in the CAte::HandleCmd function of the ATE Module's Kylin component, enabling remote unauthenticated attackers to inject and execute arbitrary commands on the device. This can lead to full compromise of the affected device.
Potential Impact
Successful exploitation allows remote attackers to execute arbitrary commands on the affected Tenda devices without authentication, potentially leading to full device compromise, disruption of network services, or unauthorized access to network traffic. The vulnerability has a CVSS 4.0 score of 9.3, reflecting high impact on confidentiality, integrity, and availability.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. No official fix or temporary workaround has been documented at this time. Users should monitor Tenda's official channels for updates and apply patches as soon as they become available. Until then, restricting remote access to affected devices and disabling unnecessary services may reduce exposure.
CVE-2026-19747: Command Injection in Tenda CH7
Description
A command injection vulnerability exists in multiple Tenda router models including CH7, CH7G, CH10, CP3 series, CP7, and TC3 series up to the build dated 20260625. The flaw is located in the CAte::HandleCmd function within the ATE Module's Kylin file. This vulnerability allows remote attackers to execute arbitrary commands on the affected devices without any authentication. The CVSS 4.0 base score is 9.3, indicating critical severity.
CVSS v4.0
Score 9.3critical
Affected software
cpe:2.3:h:tenda:ch7:*:*:*:*:*:*:*:*cpe:2.3:h:tenda:ch7g:*:*:*:*:*:*:*:*cpe:2.3:h:tenda:ch10:*:*:*:*:*:*:*:*cpe:2.3:h:tenda:cp3:*:*:*:*:*:*:*:*cpe:2.3:h:tenda:cp3_pro:*:*:*:*:*:*:*:*cpe:2.3:h:tenda:cp7:*:*:*:*:*:*:*:*AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
CVE-2026-19747 is a critical command injection vulnerability affecting several Tenda router models (CH7, CH7G, CH10, CP3, CP3 Pro, CP7, TC3B14C, TC3B15C, TC3T14C, TC3T15C) up to the 20260625 build. The vulnerability arises from improper input handling in the CAte::HandleCmd function of the ATE Module's Kylin component, enabling remote unauthenticated attackers to inject and execute arbitrary commands on the device. This can lead to full compromise of the affected device.
Potential Impact
Successful exploitation allows remote attackers to execute arbitrary commands on the affected Tenda devices without authentication, potentially leading to full device compromise, disruption of network services, or unauthorized access to network traffic. The vulnerability has a CVSS 4.0 score of 9.3, reflecting high impact on confidentiality, integrity, and availability.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. No official fix or temporary workaround has been documented at this time. Users should monitor Tenda's official channels for updates and apply patches as soon as they become available. Until then, restricting remote access to affected devices and disabling unnecessary services may reduce exposure.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- VulDB
- Date Reserved
- 2026-08-13T14:39:28.581Z
- Cvss Version
- 4.0
- State
- PUBLISHED
- Remediation Level
- null
Threat ID: 6a7e2503bf8831d539bec0f3
Added to database: 08/13/2026, 20:11:47 UTC
Last enriched: 08/13/2026, 20:26:23 UTC
Last updated: 08/13/2026, 20:26:23 UTC
Views: 5
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.