CVE-2026-19747: Command Injection in Tenda CH7
CVE-2026-19747 is a critical command injection vulnerability affecting multiple Tenda router models including CH7, CH7G, CH10, CP3, CP3 Pro, CP7, TC3B14C, TC3B15C, TC3T14C, and TC3T15C up to the build dated 20260625. The flaw exists in the CAte::HandleCmd function within the Kylin file of the ATE Module, allowing remote attackers to execute arbitrary commands. The vulnerability has a high CVSS 4.0 score of 9.3, indicating it is remotely exploitable without privileges or user interaction and can cause high impact on confidentiality, integrity, and availability. No official patch or remediation guidance is currently available, and no known exploits in the wild have been reported.
AI Analysis
Technical Summary
This vulnerability is a command injection flaw in the CAte::HandleCmd function of the Kylin file in the ATE Module of several Tenda router models up to the 20260625 build. Remote attackers can exploit this weakness to execute arbitrary commands on affected devices without authentication or user interaction. The vulnerability affects multiple models including CH7, CH7G, CH10, CP3, CP3 Pro, CP7, TC3B14C, TC3B15C, TC3T14C, and TC3T15C. The CVSS 4.0 vector indicates network attack vector, low attack complexity, no privileges required, no user interaction, and high impact on confidentiality, integrity, and availability. No vendor advisory or patch information is currently available, so remediation status is unknown.
Potential Impact
Successful exploitation allows remote attackers to execute arbitrary commands on affected Tenda devices, potentially leading to full compromise of device confidentiality, integrity, and availability. This can result in unauthorized control over the device and disruption of network services.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, restrict network access to affected devices and monitor for unusual activity. Avoid exposing vulnerable devices directly to untrusted networks.
CVE-2026-19747: Command Injection in Tenda CH7
Description
CVE-2026-19747 is a critical command injection vulnerability affecting multiple Tenda router models including CH7, CH7G, CH10, CP3, CP3 Pro, CP7, TC3B14C, TC3B15C, TC3T14C, and TC3T15C up to the build dated 20260625. The flaw exists in the CAte::HandleCmd function within the Kylin file of the ATE Module, allowing remote attackers to execute arbitrary commands. The vulnerability has a high CVSS 4.0 score of 9.3, indicating it is remotely exploitable without privileges or user interaction and can cause high impact on confidentiality, integrity, and availability. No official patch or remediation guidance is currently available, and no known exploits in the wild have been reported.
CVSS v4.0
Score 9.3critical
Affected software
Tenda
CH7
Tenda
CH7G
Tenda
CH10
Tenda
CP3
Tenda
CP3 Pro
Tenda
CP7
Tenda
TC3B14C
Tenda
TC3B15C
Tenda
TC3T14C
Tenda
TC3T15C
cpe:2.3:h:tenda:ch7:*:*:*:*:*:*:*:*cpe:2.3:h:tenda:ch7g:*:*:*:*:*:*:*:*cpe:2.3:h:tenda:ch10:*:*:*:*:*:*:*:*cpe:2.3:h:tenda:cp3:*:*:*:*:*:*:*:*cpe:2.3:h:tenda:cp3_pro:*:*:*:*:*:*:*:*cpe:2.3:h:tenda:cp7:*:*:*:*:*:*:*:*AI-Powered Analysis
Machine-generated threat intelligence
Technical Analysis
This vulnerability is a command injection flaw in the CAte::HandleCmd function of the Kylin file in the ATE Module of several Tenda router models up to the 20260625 build. Remote attackers can exploit this weakness to execute arbitrary commands on affected devices without authentication or user interaction. The vulnerability affects multiple models including CH7, CH7G, CH10, CP3, CP3 Pro, CP7, TC3B14C, TC3B15C, TC3T14C, and TC3T15C. The CVSS 4.0 vector indicates network attack vector, low attack complexity, no privileges required, no user interaction, and high impact on confidentiality, integrity, and availability. No vendor advisory or patch information is currently available, so remediation status is unknown.
Potential Impact
Successful exploitation allows remote attackers to execute arbitrary commands on affected Tenda devices, potentially leading to full compromise of device confidentiality, integrity, and availability. This can result in unauthorized control over the device and disruption of network services.
Mitigation Recommendations
Patch status is not yet confirmed — check the vendor advisory for current remediation guidance. Until an official fix is released, restrict network access to affected devices and monitor for unusual activity. Avoid exposing vulnerable devices directly to untrusted networks.
Technical Details
- Data Version
- 5.2
- Assigner Short Name
- VulDB
- Date Reserved
- 2026-08-13T14:39:28.581Z
- Cvss Version
- 4.0
- State
- PUBLISHED
Threat ID: 6a7e2503bf8831d539bec0f3
Added to database: 08/13/2026, 20:11:47 UTC
Last enriched: 08/21/2026, 14:00:46 UTC
Last updated: 09/26/2026, 01:47:40 UTC
Views: 73
Community Reviews
0 reviewsCrowdsource mitigation strategies, share intel context, and vote on the most helpful responses. Sign in to add your voice and help keep defenders ahead.
Want to contribute mitigation steps or threat intel context? Sign in or create an account to join the community discussion.
Actions
Updates to AI analysis require Pro Console access. Upgrade inside Console → Billing.
Need more coverage?
Upgrade to Pro Console for AI refresh and higher limits.
For incident response and remediation, OffSeq services can help resolve threats faster.
Latest Threats
Check if your credentials are on the dark web
Instant breach scanning across billions of leaked records. Free tier available.